Cited 0 time in
비내진 철근콘크리트 건축물의 FRP 재킷에 대한 내진보강 설계 전략
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 황희진 | - |
| dc.contributor.author | 김혜원 | - |
| dc.contributor.author | 오근영 | - |
| dc.contributor.author | 신지욱 | - |
| dc.date.accessioned | 2023-11-13T07:40:59Z | - |
| dc.date.available | 2023-11-13T07:40:59Z | - |
| dc.date.issued | 2023-11 | - |
| dc.identifier.issn | 1226-525X | - |
| dc.identifier.issn | 2234-1099 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/68439 | - |
| dc.description.abstract | Existing reinforced concrete buildings with seismically deficient details have premature failure under earthquake loads. The fiber-reinforced polymer column jacket enhances the lateral resisting capacities with additional confining pressures. This paper aims to quantify the retrofit effect varying the confinement and stiffness-related parameters under three earthquake scenarios and establish the retrofit strategy. The retrofit effects were estimated by comparing energy demands between non-retrofitted and retrofitted conditions. The retrofit design parameters are determined considering seismic hazard levels to maximize the retrofit effects. The critical parameters of the retrofit system were determined by the confinement-related parameters at moderate and high seismic levels and the stiffness-related parameters at low seismic levels. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국지진공학회 | - |
| dc.title | 비내진 철근콘크리트 건축물의 FRP 재킷에 대한 내진보강 설계 전략 | - |
| dc.title.alternative | Seismic Retrofit Scheme of FRP Column Jacketing System for Non-Seismic RC Building Frame | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5000/EESK.2023.27.6.293 | - |
| dc.identifier.bibliographicCitation | 한국지진공학회논문집, v.27, no.6, pp 293 - 301 | - |
| dc.citation.title | 한국지진공학회논문집 | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 293 | - |
| dc.citation.endPage | 301 | - |
| dc.identifier.kciid | ART003012152 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | FRP jacketing system | - |
| dc.subject.keywordAuthor | Reinforced concrete frame building | - |
| dc.subject.keywordAuthor | Seismically-deficient details | - |
| dc.subject.keywordAuthor | Retrofit effect | - |
| dc.subject.keywordAuthor | Retrofit strategy | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.