Cited 2 time in
Application of Static Headspace GC-MS Method for Selective 1,4-Dioxane Detection in Food Additives
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Myung-Chan | - |
| dc.contributor.author | Park, Su-Yeon | - |
| dc.contributor.author | Kwon, Seo-Yeon | - |
| dc.contributor.author | Kim, Yu-Kyeong | - |
| dc.contributor.author | Kim, Yeong-In | - |
| dc.contributor.author | Seo, Yong-Soo | - |
| dc.contributor.author | Cho, Sueng-Mok | - |
| dc.contributor.author | Shin, Eui-Cheol | - |
| dc.contributor.author | Mok, Jin Hong | - |
| dc.contributor.author | Lee, Yang-Bong | - |
| dc.date.accessioned | 2023-09-22T02:42:06Z | - |
| dc.date.available | 2023-09-22T02:42:06Z | - |
| dc.date.issued | 2023-09 | - |
| dc.identifier.issn | 2304-8158 | - |
| dc.identifier.issn | 2304-8158 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/67954 | - |
| dc.description.abstract | Efficient detection methods must be developed for 1,4-dioxane due to its suspected status as a human carcinogen, which is highly mobile in food and environmental resources. In this regard, this experiment has been conducted to develop reliable and selective detection and measurement methods by using static headspace (SH) isolation, followed by gas chromatography–mass spectrometry (GC-MS). A new method was developed for determining the spiked 1,4-dioxane contents in a polyethylene glycol 600 (PEG 600). The optimal condition for SH-GC-MS was discussed. The representative ions of 1,4-dioxane and 1,4-dioxane-d8 in the SIM mode of MS are 88 and 96, respectively, and the peaks of the SIM mode were separated and confirmed. The linear range for the method covers 0.25 to 100 mg/L with a coefficient of determination (R2) ≥ 0.999. The method applicability was demonstrated by spike recovery across a variety of food additives (i.e., chlorine bitartrate, choline chloride, polysorbate 20 and 60, and PEG 1000). All spike recovery from the tested samples was in the range of 89.50–102.68% with a precision of 0.44–11.22%. These findings suggest a new analytical method for food safety inspection, and could be applicable for ensuring the safety of foods and environmental and public health on a broad scale. © 2023 by the authors. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI AG | - |
| dc.title | Application of Static Headspace GC-MS Method for Selective 1,4-Dioxane Detection in Food Additives | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/foods12173299 | - |
| dc.identifier.scopusid | 2-s2.0-85170256135 | - |
| dc.identifier.wosid | 001061066500001 | - |
| dc.identifier.bibliographicCitation | Foods, v.12, no.17 | - |
| dc.citation.title | Foods | - |
| dc.citation.volume | 12 | - |
| dc.citation.number | 17 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Food Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Food Science & Technology | - |
| dc.subject.keywordAuthor | limit of detection | - |
| dc.subject.keywordAuthor | limit of quantification | - |
| dc.subject.keywordAuthor | method validation | - |
| dc.subject.keywordAuthor | polyethylene glycol | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
