Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Application of Static Headspace GC-MS Method for Selective 1,4-Dioxane Detection in Food Additives

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Myung-Chan-
dc.contributor.authorPark, Su-Yeon-
dc.contributor.authorKwon, Seo-Yeon-
dc.contributor.authorKim, Yu-Kyeong-
dc.contributor.authorKim, Yeong-In-
dc.contributor.authorSeo, Yong-Soo-
dc.contributor.authorCho, Sueng-Mok-
dc.contributor.authorShin, Eui-Cheol-
dc.contributor.authorMok, Jin Hong-
dc.contributor.authorLee, Yang-Bong-
dc.date.accessioned2023-09-22T02:42:06Z-
dc.date.available2023-09-22T02:42:06Z-
dc.date.issued2023-09-
dc.identifier.issn2304-8158-
dc.identifier.issn2304-8158-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/67954-
dc.description.abstractEfficient detection methods must be developed for 1,4-dioxane due to its suspected status as a human carcinogen, which is highly mobile in food and environmental resources. In this regard, this experiment has been conducted to develop reliable and selective detection and measurement methods by using static headspace (SH) isolation, followed by gas chromatography–mass spectrometry (GC-MS). A new method was developed for determining the spiked 1,4-dioxane contents in a polyethylene glycol 600 (PEG 600). The optimal condition for SH-GC-MS was discussed. The representative ions of 1,4-dioxane and 1,4-dioxane-d8 in the SIM mode of MS are 88 and 96, respectively, and the peaks of the SIM mode were separated and confirmed. The linear range for the method covers 0.25 to 100 mg/L with a coefficient of determination (R2) ≥ 0.999. The method applicability was demonstrated by spike recovery across a variety of food additives (i.e., chlorine bitartrate, choline chloride, polysorbate 20 and 60, and PEG 1000). All spike recovery from the tested samples was in the range of 89.50–102.68% with a precision of 0.44–11.22%. These findings suggest a new analytical method for food safety inspection, and could be applicable for ensuring the safety of foods and environmental and public health on a broad scale. © 2023 by the authors.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI AG-
dc.titleApplication of Static Headspace GC-MS Method for Selective 1,4-Dioxane Detection in Food Additives-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/foods12173299-
dc.identifier.scopusid2-s2.0-85170256135-
dc.identifier.wosid001061066500001-
dc.identifier.bibliographicCitationFoods, v.12, no.17-
dc.citation.titleFoods-
dc.citation.volume12-
dc.citation.number17-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaFood Science & Technology-
dc.relation.journalWebOfScienceCategoryFood Science & Technology-
dc.subject.keywordAuthorlimit of detection-
dc.subject.keywordAuthorlimit of quantification-
dc.subject.keywordAuthormethod validation-
dc.subject.keywordAuthorpolyethylene glycol-
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 식품공학부 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Eui Cheol photo

Shin, Eui Cheol
농업생명과학대학 (식품공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE