Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Effects of size and shape of the side holes of a double J stent on the ureter fluid flow after stenosis

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Seung Bae-
dc.contributor.authorKim, Kyung-Wuk-
dc.contributor.authorPark, Se-Hyun-
dc.contributor.authorBaba, Yasutaka-
dc.contributor.authorLee, Changje-
dc.contributor.authorChoi, Young Ho-
dc.contributor.authorKim, Hyoung-Ho-
dc.date.accessioned2023-09-05T01:41:49Z-
dc.date.available2023-09-05T01:41:49Z-
dc.date.issued2024-09-
dc.identifier.issn1025-5842-
dc.identifier.issn1476-8259-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/67696-
dc.description.abstractThe effect of side holes morphology changes in double J stent (DJS) on encrustation was analyzed using computational fluid dynamics (CFD). We analyzed DJS side holes with inner diameter of 1 mm and outer diameters of 1 (type A), 1.2 (type B) and 1.4 (type C) mm, respectively. Concentric stenosis with three intraureteral degree (0%, 12%, and 88%) was analyzed. The flow rate, shear stress and wall shear stress (WSS) distribution were investigated. Urine flow through SH1 before the ureteropelvic junction (UPJ) differed based on the ureteral stenosis degree. The sum of flow rates through the SHs increased with diameter. In the stented ureter with 12% stenosis, the flow rate through SH1 approximately doubled than that without ureteral stenosis, and the flow rate through SH1 was maximal for the type ‘C’ stent in both 12% and 88% ureteral stenosis. The mean shear stress in the SHs increased with the degree of stenosis. The WSS around the SHs was higher for type ‘C’ than types A and B. From the flow rates and shear stresses in and around the SHs, the larger SH diameter of the DJS from the UPJ to mid-ureter is expected to induce encrustation reduction, especially in patients with urinary lithiasis. © 2023 Informa UK Limited, trading as Taylor & Francis Group.-
dc.format.extent14-
dc.language영어-
dc.language.isoENG-
dc.publisherTaylor & Francis-
dc.titleEffects of size and shape of the side holes of a double J stent on the ureter fluid flow after stenosis-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1080/10255842.2023.2252550-
dc.identifier.scopusid2-s2.0-85169167874-
dc.identifier.wosid001062018500001-
dc.identifier.bibliographicCitationComputer Methods in Biomechanics and Biomedical Engineering, v.27, no.12, pp 1596 - 1609-
dc.citation.titleComputer Methods in Biomechanics and Biomedical Engineering-
dc.citation.volume27-
dc.citation.number12-
dc.citation.startPage1596-
dc.citation.endPage1609-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryComputer Science, Interdisciplinary Applications-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.subject.keywordPlusNUMERICAL-SIMULATION-
dc.subject.keywordPlusPERISTALSIS-
dc.subject.keywordPlusCALCIUM-
dc.subject.keywordPlusURINE-
dc.subject.keywordPlusSTONE-
dc.subject.keywordPlusENCRUSTATION-
dc.subject.keywordAuthorcomputational fluid dynamics (CFD)-
dc.subject.keywordAuthorDouble J stent-
dc.subject.keywordAuthorencrustation-
dc.subject.keywordAuthorurine flow-
dc.subject.keywordAuthorwall shear stress-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공학계열 > 산업시스템공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyoung Ho photo

Kim, Hyoung Ho
우주항공대학 (항공우주공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE