Cited 3 time in
Novel Current Slope Control in Dual-Active-Bridge Converter Using Periodic Filters and Direct Access Memory in DSP
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Jin Wook | - |
| dc.contributor.author | Le, Tuan-Vi | - |
| dc.contributor.author | Kang, Feel-soon | - |
| dc.contributor.author | Park, Sung-Jun | - |
| dc.date.accessioned | 2023-08-29T08:40:31Z | - |
| dc.date.available | 2023-08-29T08:40:31Z | - |
| dc.date.issued | 2024-03 | - |
| dc.identifier.issn | 1975-0102 | - |
| dc.identifier.issn | 2093-7423 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/67655 | - |
| dc.description.abstract | This paper proposes a new current slope control to reduce the current peak in a dual-active-bridge (DAB) converter. It detects the current slope at two specific points in the DAB converter current and uses the current slope ratio as the control command value. We propose a periodic filter method to reduce CPU load and prevent noise and phase delay by implementing high-speed sampling using DSP's DMA (Direct Memory Access) function. The proposed method is based on SPS (Single Phase Shift) modulation rather than the conventional complex control method. It maintains the phase difference of the voltage across the DAB converter to be minimized. Therefore, since the generation of circulating current is suppressed, reactive power is reduced, efficiency is improved, and the current peak is reduced, thereby decreasing switch conduction loss and the core size of the magnetic component. The proposed current slope control method is applied to a dc-to-dc converter composed of a DAB converter and a non-isolated converter. We verify technical feasibility and excellence through simulations and experiments. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | SPRINGER SINGAPORE PTE LTD | - |
| dc.title | Novel Current Slope Control in Dual-Active-Bridge Converter Using Periodic Filters and Direct Access Memory in DSP | - |
| dc.title.alternative | Novel Current Slope Control in Dual-Active-Bridge Converter Using Periodic Filters and Direct Access Memory in DSP | - |
| dc.type | Article | - |
| dc.publisher.location | 싱가폴 | - |
| dc.identifier.doi | 10.1007/s42835-023-01609-6 | - |
| dc.identifier.scopusid | 2-s2.0-85167796771 | - |
| dc.identifier.wosid | 001048084500001 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, v.19, no.3, pp 1417 - 1427 | - |
| dc.citation.title | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY | - |
| dc.citation.volume | 19 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 1417 | - |
| dc.citation.endPage | 1427 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003056860 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.subject.keywordPlus | DC-DC CONVERTER | - |
| dc.subject.keywordPlus | MODULATION STRATEGY | - |
| dc.subject.keywordPlus | DC/DC CONVERTER | - |
| dc.subject.keywordPlus | ZVS | - |
| dc.subject.keywordPlus | VOLTAGE | - |
| dc.subject.keywordPlus | OPTIMIZATION | - |
| dc.subject.keywordPlus | RANGE | - |
| dc.subject.keywordAuthor | Current slope control | - |
| dc.subject.keywordAuthor | Direct memory access (DMA) | - |
| dc.subject.keywordAuthor | Dual active bridge (DAB) | - |
| dc.subject.keywordAuthor | Digital signal processor (DSP) | - |
| dc.subject.keywordAuthor | Periodic filter | - |
| dc.subject.keywordAuthor | Phase shift modulation (PSM) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.