Cited 17 time in
Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Choi, Bo Hwa | - |
| dc.contributor.author | Baek, Hye Jin | - |
| dc.contributor.author | Ha, Ji Young | - |
| dc.contributor.author | Ryu, Kyeong Hwa | - |
| dc.contributor.author | Moon, Jin Il | - |
| dc.contributor.author | Park, Sung Eun | - |
| dc.contributor.author | Bae, Kyungsoo | - |
| dc.contributor.author | Jeon, Kyung Nyeo | - |
| dc.contributor.author | Jung, Eun Jung | - |
| dc.date.accessioned | 2022-12-26T12:31:28Z | - |
| dc.date.available | 2022-12-26T12:31:28Z | - |
| dc.date.issued | 2020-09 | - |
| dc.identifier.issn | 1229-6929 | - |
| dc.identifier.issn | 2005-8330 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/6249 | - |
| dc.description.abstract | Objective: To investigate the clinical feasibility of synthetic diffusion-weighted imaging (sDWI) at different b-values in patients with breast cancer by assessing the diagnostic image quality and the quantitative measurements compared with conventional diffusion-weighted imaging (cDWI). Materials and Methods: Fifty patients with breast cancer were assessed using cDWI at b-values of 800 and 1500 s/mm(2) (cDWI(800) and cDWI(1500)) and sDWI at b-values of 1000 and 1500 s/mm(2) (sDWI(1000) and sDWI(1500)). Qualitative analysis (normal glandular tissue suppression, overall image quality, and lesion conspicuity) was performed using a 4-point Likert-scale for all DWI sets and the cancer detection rate (CDR) was calculated. We also evaluated cancer-to-parenchyma contrast ratios for each DWI set in 45 patients with the lesion identified on any of the DWI sets. Statistical comparisons were performed using Friedman test, one-way analysis of variance, and Cochran's Q test. Results: All parameters of qualitative analysis, cancer-to-parenchyma contrast ratios, and CDR increased with increasing b-values, regardless of the type of imaging (synthetic or conventional) (p < 0.001). Additionally, sDWI(1500) provided better lesion conspicuity than cDWI(1500) (3.52 +/- 0.92 vs. 3.39 +/- 0.90, p < 0.05). Although cDWI(1500) showed better normal glandular tissue suppression and overall image quality than sDWI(1500) (3.66 +/- 0.78 and 3.73 +/- 0.62 vs. 3.32 +/- 0.90 and 3.35 +/- 0.81, respectively; p < 0.05), there was no significant difference in their CDR (90.0%). Cancer-to-parenchyma contrast ratios were greater in sDWI(1500) than in cDWI1500 (0.63 +/- 0.17 vs. 0.55 +/- 0.18, p < 0.001). Conclusion: sDWI(1500) can be feasible for evaluating breast cancers in clinical practice. It provides higher tumor conspicuity, better cancer-to-parenchyma contrast ratio, and comparable CDR when compared with cDWI(1500). | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한영상의학회 | - |
| dc.title | Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3348/kjr.2019.0568 | - |
| dc.identifier.scopusid | 2-s2.0-85088448897 | - |
| dc.identifier.wosid | 000550662500002 | - |
| dc.identifier.bibliographicCitation | Korean Journal of Radiology, v.21, no.9, pp 1036 - 1044 | - |
| dc.citation.title | Korean Journal of Radiology | - |
| dc.citation.volume | 21 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 1036 | - |
| dc.citation.endPage | 1044 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002614554 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | ECHO DIXON TECHNIQUE | - |
| dc.subject.keywordPlus | B-VALUE | - |
| dc.subject.keywordPlus | PROSTATE | - |
| dc.subject.keywordPlus | COEFFICIENT | - |
| dc.subject.keywordPlus | AGREEMENT | - |
| dc.subject.keywordPlus | CONTRAST | - |
| dc.subject.keywordPlus | S/MM(2) | - |
| dc.subject.keywordPlus | IMAGES | - |
| dc.subject.keywordPlus | KAPPA | - |
| dc.subject.keywordPlus | 3D | - |
| dc.subject.keywordAuthor | Breast cancer | - |
| dc.subject.keywordAuthor | b-value | - |
| dc.subject.keywordAuthor | Diffusion-weighted imaging | - |
| dc.subject.keywordAuthor | MRI | - |
| dc.subject.keywordAuthor | Synthetic MRI | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
