One-step immunoassay without washing steps for influenza A virus detection using ISFET

Authors
심원보Bong, JH (Bong, Ji-Hong)Kim, HR (Kim, Hong-Rae)Yoo, JW (Yoo, Jae-Woo)Kang, MJ (Kang, Min-Jung)Shin, MG (Shin, Myung-Geun)Lee, JS (Lee, Jung-Su)Lee, SD (Lee, Sang-Dae)Pyun, JC (Pyun, Jae-Chul)
Issue Date
Oct-2020
Publisher
Pergamon Press Ltd.
Citation
Biosensors and Bioelectronics, v.165
Indexed
SCIE
SCOPUS
Journal Title
Biosensors and Bioelectronics
Volume
165
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/6086
ISSN
0956-5663
1873-4235
Abstract
A one-step immunoassay for influenza A virus detection was developed using two different microbeads and a filter-inserted bottle. Two bead types with diameters of 15 (capture bead) and 3 (detection bead) mu m were prepared to specifically detect influenza A virus. Anti-influenza A virus antibodies were coated on both bead types, whereas urease was immobilized only on the detection bead. An influenza A-positive sample could form a sandwich complex with the capture and detection beads; this complex would not pass through the filter, which had a controlled pore size. As the detection bead was used at a limiting concentration, it would be prevented from crossing the filter; thus, it would further react with the substrate urea and consequently increase the pH. An influenza A-negative sample would fail to form the sandwich complex in the presence of the capture and detection beads. Accordingly, the detection bead would pass through the filter into the urea buffer and increase the pH. The pH change in the urease reaction could be quantitatively measured by an indicator such as phenol red or using ion-selective field-effect transistor (ISFET). This one-step immunoassay was used for the detection of influenza A virus in real samples. The receiver operating characteristic (ROC) plot analysis showed an area under the curve (AUC) value of 0.931; the sensitivity and specificity of the assay was 80% and 90%, respectively, at a cutoff value of 0.9986. These results demonstrate that the one-step immunoassay could increase the sensitivity of influenza A virus detection in real samples.
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 식품공학부 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shim, Won Bo photo

Shim, Won Bo
농업생명과학대학 (식품공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE