Detailed Information

Cited 2 time in webofscience Cited 4 time in scopus
Metadata Downloads

Added Value of Cone-Beam Computed Tomography for Detecting Hepatocellular Carcinomas and Feeding Arteries during Transcatheter Arterial Chemoembolization Focusing on Radiation Exposure

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Duk-Ju-
dc.contributor.authorChul-Nam, In-
dc.contributor.authorPark, Sung-Eun-
dc.contributor.authorKim, Doo-Ri-
dc.contributor.authorLee, Jeong-Sub-
dc.contributor.authorKim, Bong-Soo-
dc.contributor.authorChoi, Guk-Myung-
dc.contributor.authorKim, JeongJae-
dc.contributor.authorWon, Jung-Ho-
dc.date.accessioned2023-07-19T04:41:30Z-
dc.date.available2023-07-19T04:41:30Z-
dc.date.issued2023-06-
dc.identifier.issn1010-660X-
dc.identifier.issn1648-9144-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/59751-
dc.description.abstractBackground and Objectives: This study aimed to evaluate the added value of cone-beam computed tomography (CBCT) for detecting hepatocellular carcinomas (HCC) and feeding arteries during transcatheter arterial chemoembolization (TACE). Material and methods: Seventy-six patients underwent TACE and CBCT. We subcategorized patients into groups I (61 patients: possible superselection of tumor/feeding arteries) and II (15 patients: limited superselection of tumor/feeding arteries). We evaluated fluoroscopy time and radiation dose during TACE. Two blinded radiologists independently performed an interval reading based on digital subtraction angiography (DSA) imaging only and DSA combined with CBCT in group I. Result: The mean total fluoroscopy time was 1456.3 & PLUSMN; 605.6 s. The mean dose-area product (DAP), mean DAP of CBCT, and mean ratio of DAP of CBCT to total DAP was 137.1 & PLUSMN; 69.2 Gy cm(2), 18.3 & PLUSMN; 7.1 Gy cm(2), and 13.3%, respectively. The sensitivity for detecting HCC increased after the additional CBCT reading, from 69.6% to 97.3% and 69.6% to 96.4% for readers 1 and 2, respectively. The sensitivity for detecting feeding arteries increased from 60.3% to 96.6% and 63.8% to 97.4% for readers 1 and 2, respectively. Conclusions: CBCT can increase sensitivity for detecting HCCs and feeding arteries without significantly increasing the radiation exposure.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleAdded Value of Cone-Beam Computed Tomography for Detecting Hepatocellular Carcinomas and Feeding Arteries during Transcatheter Arterial Chemoembolization Focusing on Radiation Exposure-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/medicina59061121-
dc.identifier.scopusid2-s2.0-85163730332-
dc.identifier.wosid001015423500001-
dc.identifier.bibliographicCitationMedicina (Kaunas, Lithuania), v.59, no.6-
dc.citation.titleMedicina (Kaunas, Lithuania)-
dc.citation.volume59-
dc.citation.number6-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusTRANSARTERIAL CHEMOEMBOLIZATION-
dc.subject.keywordPlusCT-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusTACE-
dc.subject.keywordAuthorchemoembolization-
dc.subject.keywordAuthorhepatocellular carcinoma-
dc.subject.keywordAuthorcone-beam computed tomography-
dc.subject.keywordAuthorradiation exposure-
dc.subject.keywordAuthorsensitivity-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE