Detailed Information

Cited 9 time in webofscience Cited 11 time in scopus
Metadata Downloads

Determination and comparison of freely dissolved PAHs using different types of passive samplers in freshwater

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Na Yeong-
dc.contributor.authorLoganathan, Bommanna G.-
dc.contributor.authorKim, Gi Beum-
dc.date.accessioned2023-06-28T08:40:23Z-
dc.date.available2023-06-28T08:40:23Z-
dc.date.issued2023-09-
dc.identifier.issn0048-9697-
dc.identifier.issn1879-1026-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/59683-
dc.description.abstractPolycyclic aromatic hydrocarbons (PAHs) are well-known for their recalcitrant properties and biotoxicity in organisms, leading to serious environmental and health problems. Despite various analytical methods available, accurate determination of the bioavailable fraction is warranted in order to evaluate the precise toxic potentials of these compounds. Currently, the passive sampler is used worldwide to measure the bioavailable PAHs in the environment using the equilibrium partitioning principle. In this study, we co-deployed different types of passive samplers, which are linear low-density polyethylene (LLDPE) and low-density polyethylene (LDPE), to determine freely dissolved concentrations (Cfree) of PAHs using the performance reference compounds (PRCs) in Kentucky Lake (KL), Ohio River (OH), and Mississippi River (MS). The fractional equilibrium (feq) of BeP-d12 was observed to be high in LLDPE compared with LDPE in OH and MS. In contrast, the feq of all PRCs was similar in both passive samplers in KL due to slow flow velocity. The sum of average freely dissolved PAH concentrations in LLDPE and LDPE during the exposure period were 2.89 and 1.27 ng/L in KL, 8.13 and 3.31 ng/L in OH, and 5.19 and 3.82 ng/L in MS, respectively. The results revealed that LLDPE is a suitable alternative tool to LDPE for both short-term and long-term monitoring of PAHs. © 2023 Elsevier B.V.-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleDetermination and comparison of freely dissolved PAHs using different types of passive samplers in freshwater-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/j.scitotenv.2023.164802-
dc.identifier.scopusid2-s2.0-85162099532-
dc.identifier.wosid001025988900001-
dc.identifier.bibliographicCitationScience of the Total Environment, v.892-
dc.citation.titleScience of the Total Environment-
dc.citation.volume892-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.subject.keywordPlusPOLYCYCLIC AROMATIC-HYDROCARBONS-
dc.subject.keywordPlusLOW-DENSITY POLYETHYLENE-
dc.subject.keywordPlusSEMIPERMEABLE-MEMBRANE DEVICES-
dc.subject.keywordPlusPERFORMANCE REFERENCE COMPOUNDS-
dc.subject.keywordPlusPOLYCHLORINATED-BIPHENYLS PCBS-
dc.subject.keywordPlusHYDROPHOBIC ORGANIC-COMPOUNDS-
dc.subject.keywordPlusTRACE-METALS-
dc.subject.keywordPlusUPTAKE RATES-
dc.subject.keywordPlusCONTAMINANTS-
dc.subject.keywordPlusRIVER-
dc.subject.keywordAuthorFreactional equilibrium-
dc.subject.keywordAuthorFreely dissolved concentration-
dc.subject.keywordAuthorLLDPE-
dc.subject.keywordAuthorPassive sampler-
dc.subject.keywordAuthorPolycyclic Aromatic Hydrocarbon (PAHs)-
dc.subject.keywordAuthorRiver-
Files in This Item
There are no files associated with this item.
Appears in
Collections
해양과학대학 > Department of Marine Environmental Engineering > Journal Articles
공학계열 > 해양환경공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Gi Beum photo

Kim, Gi Beum
해양과학대학 (해양환경공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE