Detailed Information

Cited 8 time in webofscience Cited 10 time in scopus
Metadata Downloads

Closed Hydroponic Nutrient Solution Management Using Multiple Water SourcesClosed Hydroponic Nutrient Solution Management Using Multiple Water Sources

Other Titles
Closed Hydroponic Nutrient Solution Management Using Multiple Water Sources
Authors
Kim, J.S.Kim, H.-J.Gang, M.-S.Kim, D.-W.Cho, W.-J.Jang, J.K.
Issue Date
Jun-2023
Publisher
Springer Nature
Keywords
Ion-selective electrodes; Ion-specific nutrient solution management; Nutriculture; Precision nutrient solution supply
Citation
Journal of Biosystems Engineering, v.48, no.2, pp 215 - 224
Pages
10
Indexed
SCOPUS
KCI
Journal Title
Journal of Biosystems Engineering
Volume
48
Number
2
Start Page
215
End Page
224
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/59521
DOI
10.1007/s42853-023-00182-0
ISSN
1738-1266
2234-1862
Abstract
Purpose: A properly ion-balanced nutrient solution is vital for plant growth. However, when reusing a nutrient solution, the nutrient balance is likely to fluctuate and become unsuitable for irrigation. Ionic imbalance problems that cause plant growth disorders in nutrient solutions can be minimized if the nutrient concentration of the various water sources can be determined and considered when making the nutrient solution. In this study, a closed hydroponic nutrient management algorithm for multiple water sources was developed. Methods: The concentrations of NO3−, K+, and Ca2+ ions in the nutrient solution and various water sources were measured in real time and calculated to automatically replenish insufficient ions. For this purpose, ion-selective electrodes (ISEs) were selected for the determination of NO3−, K+, and Ca2+ ion concentrations and eight stock solutions for individual salt replenishment. Results: Performance tests were conducted to verify the developed system’s ability to maintain NO3−, K+, and Ca2+ ion concentrations at their target values. The nutrient solution dosing accuracy obtained in the stepwise management test was evaluated using root mean square error (RMSE). In addition, long-term performance evaluation of the developed algorithm was validated while growing lettuce using the closed nutrient film technique (NFT). The long-term accuracy of the developed system was RMSE 60.6, 21.0, and 9.86 mg/L for the NO3−, K+, and Ca2+ ions, respectively. Conclusion: The results of this study showed nutrient management using multiple water sources by applying three different ISE sensors, NO3−, K+, and Ca2+. With the further development of ISE technology, it would be possible to control all six macronutrients in the nutrient solution. © 2023, The Author(s), under exclusive licence to The Korean Society for Agricultural Machinery.
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Woo Jae photo

Cho, Woo Jae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE