Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Cooperative Control of Two Single-Phase Full-Bridge Structures Composed of Master and Damping Inverter for Output Voltage StabilizationCooperative Control of Two Single-Phase Full-Bridge Structures Composed of Master and Damping Inverter for Output Voltage Stabilization

Other Titles
Cooperative Control of Two Single-Phase Full-Bridge Structures Composed of Master and Damping Inverter for Output Voltage Stabilization
Authors
Choi, E.-K.Kim, S.-Y.Kang, F.-S.Park, S.-J.
Issue Date
Jul-2023
Publisher
Korean Institute of Electrical Engineers
Keywords
Pulse width modulation (PWM); Single-phase; Stand-alone; Total harmonic distortion (THD); Voltage damping; Voltage source inverter (VSI)
Citation
Journal of Electrical Engineering and Technology, v.18, no.4, pp 3033 - 3047
Pages
15
Indexed
SCIE
SCOPUS
KCI
Journal Title
Journal of Electrical Engineering and Technology
Volume
18
Number
4
Start Page
3033
End Page
3047
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/59315
DOI
10.1007/s42835-023-01478-z
ISSN
1975-0102
2093-7423
Abstract
In a stand-alone inverter, a high-quality sinusoidal output of a constant voltage and constant frequency must be supplied to the load regardless of the load condition. Therefore, the THD of the output voltage in steady-state should be low and the ability to recover from the transient period needs to be fast for the load variations. However, when the inverter employs an LC filter at the output stage, a damping technique is required to suppress voltage oscillations due to resonance when the load changes. This paper proposes a damping control method to stabilize the output voltage using cooperative control of two single-phase inverters connected in parallel. The Master inverter controls the output voltage, and the Damping inverter controls the output current to support output voltage damping and power capacity. Each inverter output stage consists of a lossless filter with no damping resistor to prevent efficiency degradation and robust against system parameter changes. The output voltage distortion is less than the conventional method, regardless of loads and load variations. We carried out PSIM simulations and experiments to verify the superiority of the proposed approach. © 2023, The Author(s) under exclusive licence to The Korean Institute of Electrical Engineers.
Files in This Item
There are no files associated with this item.
Appears in
Collections
융합기술공과대학 > Division of Mechatronics Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Feel-soon photo

Kang, Feel-soon
IT공과대학 (메카트로닉스공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE