Cited 17 time in
Numerical analysis on the hygrothermal behavior of building envelope according to CLT wall assembly considering the hygrothermal-environmental zone in Korea
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Chang, Seong Jin | - |
| dc.contributor.author | Yoo, Jiwon | - |
| dc.contributor.author | Wi, Seunghwan | - |
| dc.contributor.author | Kim, Sumin | - |
| dc.date.accessioned | 2022-12-26T12:04:42Z | - |
| dc.date.available | 2022-12-26T12:04:42Z | - |
| dc.date.issued | 2020-12 | - |
| dc.identifier.issn | 0013-9351 | - |
| dc.identifier.issn | 1096-0953 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/5833 | - |
| dc.description.abstract | As buildings generally have become larger and more airtight, the ventilation rate has decreased further, causing insufficient ventilation which leads to moisture problems such as condensation, mold growth, reduction of thermal insulation performance and corrosion of building materials. In order to prevent moisture problems, it is essential to understand the thermal and hygric status of a climatic region. In this study, the hygrothermal environmental zone considering not only the thermal environment but also the hygric environment was derived by analyzing the climate environment in Korea. The hygrothermal environmental zone has the advantage of being able to take into account the hygrothermal environment of the unexplored regions and to cope with climate change by quantifying the thermal and hygric environmental indexes in each region. Finally, the long-term moisture risk of the building envelopes was evaluated. As the results, it is considered that the proposed hygrothermal environmental zone is appropriate and it is necessary to consider the hygric environment in order to secure the moisture stability of the building envelope. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Academic Press | - |
| dc.title | Numerical analysis on the hygrothermal behavior of building envelope according to CLT wall assembly considering the hygrothermal-environmental zone in Korea | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1016/j.envres.2020.110198 | - |
| dc.identifier.scopusid | 2-s2.0-85091210897 | - |
| dc.identifier.wosid | 000587971600151 | - |
| dc.identifier.bibliographicCitation | Environmental Research, v.191 | - |
| dc.citation.title | Environmental Research | - |
| dc.citation.volume | 191 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
| dc.relation.journalResearchArea | Public, Environmental & Occupational Health | - |
| dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
| dc.relation.journalWebOfScienceCategory | Public, Environmental & Occupational Health | - |
| dc.subject.keywordPlus | MOLD GROWTH | - |
| dc.subject.keywordPlus | MOISTURE | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | INSULATION | - |
| dc.subject.keywordAuthor | Regional classification | - |
| dc.subject.keywordAuthor | Hygrothermal environmental zone | - |
| dc.subject.keywordAuthor | Cross-laminated timber house | - |
| dc.subject.keywordAuthor | Moisture problem | - |
| dc.subject.keywordAuthor | Energy performance | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
