Cross-calibration of bone mineral densities and body composition between GE lunar prodigy and osteosys primus
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ha, Y.-C. | - |
| dc.contributor.author | Yoo, J.-I. | - |
| dc.date.accessioned | 2022-12-26T12:01:07Z | - |
| dc.date.available | 2022-12-26T12:01:07Z | - |
| dc.date.issued | 2021-08 | - |
| dc.identifier.issn | 2287-6375 | - |
| dc.identifier.issn | 2287-7029 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/5635 | - |
| dc.description.abstract | Background: The aim of this study was to investigate the correlation between bone mineral density (BMD) and body composition measured by the Osteosys Primus® and the GE Lunar Prodigy® and to calculate the conversion rate between the 2 devices. Methods: The 40 subjects were men and women in aged 20 to 29 years old. All participants were scanned twice on both the Osteosys Primus (OsteoSys) and the GE Lunar Prodigy (GE Healthcare) DXA systems using the manufacturers' standard scanning and positioning protocols. Results: Compared to the GE Lunar device, the mean Osteosys fat mass was overestimated to be 12.1% (1,776.9 g) in the whole body, 5.1% (163.9 g) in gynoid, and 6.7% (87.2 g) in android. Compared with the GE Lunar device, the mean BMDs of the Osteosys Primus were underestimated to be 2.3% (0.023 g/cm2) in the whole body and 3.1% (0.035 g/cm2) in L1-4. Compared with the GE Lunar device, the mean lean mass derived by the Osteosys Primus were underestimated to 2.3% (1,045.3 g) in the total body, 3.8% (179.4 g) in arms, and 7.7% (1,104.8 g) in legs, respectively. There were a strong correlation of BMD and body composition between both groups. Conclusions: Linear correction equations were developed to ensure comparability of BMD and muscle mass between the Osteosys Primus and the GE Lunar Prodigy. Importantly, use of equations from previous studies would have increased the discrepancy between the Osteosys Primus and the GE Lunar Prodigy. ? 2021 The Korean Society for Bone and Mineral Research | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Korean Society for Bone and Mineral Research | - |
| dc.title | Cross-calibration of bone mineral densities and body composition between GE lunar prodigy and osteosys primus | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.11005/JBM.2021.28.3.215 | - |
| dc.identifier.scopusid | 2-s2.0-85115337507 | - |
| dc.identifier.bibliographicCitation | Journal of Bone Metabolism, v.28, no.3, pp 215 - 221 | - |
| dc.citation.title | Journal of Bone Metabolism | - |
| dc.citation.volume | 28 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 215 | - |
| dc.citation.endPage | 221 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002752507 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Absorptiometry | - |
| dc.subject.keywordAuthor | Body composition | - |
| dc.subject.keywordAuthor | Bone density | - |
| dc.subject.keywordAuthor | Calibration | - |
| dc.subject.keywordAuthor | Photon | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.