Cited 1 time in
Does bone mineral density differ between fan-beam and pencil-beam?: A meta-analysis and systemic review
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Yoon, B.-H. | - |
| dc.contributor.author | Koh, Y.D. | - |
| dc.contributor.author | Yoo, J.-I. | - |
| dc.contributor.author | Kim, S. | - |
| dc.contributor.author | Lee, G.Y. | - |
| dc.contributor.author | Park, S.B. | - |
| dc.contributor.author | Ha, Y.-C. | - |
| dc.date.accessioned | 2022-12-26T12:00:54Z | - |
| dc.date.available | 2022-12-26T12:00:54Z | - |
| dc.date.issued | 2021-02 | - |
| dc.identifier.issn | 2287-6375 | - |
| dc.identifier.issn | 2287-7029 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/5605 | - |
| dc.description.abstract | Background: Dual energy X-ray absorptiometry (DXA) has evolved from pencil-beam (PB) to narrow fan-beam (FB) densitometers. We performed a meta-analysis of the available observational studies to determine how different modes of DXA affect bone mineral density (BMD) measurements. Methods: A total of 1,233 patients (808 women) from 14 cohort studies were included. We evaluated the differences in BMD according to the DXA mode: PB and FB. Additionally, we evaluated the differences in BMD between the 2 types of FB mode: FB (Prodigy) and the most recent FB (iDXA). Pairwise meta-analysis was performed, and weighted mean differences (WMD) were calculated for (total lumbar, total hip, and total body). Results: No significant difference was observed in total lumbar (pooled WMD, -0.013; P=0.152) and total hip BMD (pooled WMD, -0.01; P=0.889), between PB and FB. However, total body BMD was significantly lower in the PB compared to the FB group (pooled WMD, -0.014; P=0.024). No significant difference was observed in lumbar BMD (pooled WMD, -0.006; P=0.567), total hip (pooled WMD, -0.002; P=0.821), and total body (pooled WMD, 0.015; P=0.109), between Prodigy and iDXA. Conclusions: The results of this study warrant the recommendation that correction equations should not be used when comparing BMD from different modes. Further research is still needed to highlight the ways in which differences between DXA systems can be minimized. Copyright ? 2021 The Korean Society for Bone and Mineral Research. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Korean Society for Bone and Mineral Research | - |
| dc.title | Does bone mineral density differ between fan-beam and pencil-beam?: A meta-analysis and systemic review | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.11005/JBM.2021.28.1.67 | - |
| dc.identifier.scopusid | 2-s2.0-85104272771 | - |
| dc.identifier.bibliographicCitation | Journal of Bone Metabolism, v.28, no.1, pp 67 - 77 | - |
| dc.citation.title | Journal of Bone Metabolism | - |
| dc.citation.volume | 28 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 67 | - |
| dc.citation.endPage | 77 | - |
| dc.type.docType | Review | - |
| dc.identifier.kciid | ART002692362 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Absorptiometry | - |
| dc.subject.keywordAuthor | Bone density | - |
| dc.subject.keywordAuthor | Densitometry | - |
| dc.subject.keywordAuthor | Osteoporosis | - |
| dc.subject.keywordAuthor | Photon | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
