Effect of Injection Temperature Condition on Root Mean Square and Peak-to-Valley of F-theta Lens
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박용우 | - |
| dc.contributor.author | 문성민 | - |
| dc.contributor.author | 류성기 | - |
| dc.date.accessioned | 2022-12-26T11:45:44Z | - |
| dc.date.available | 2022-12-26T11:45:44Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.issn | 1598-6721 | - |
| dc.identifier.issn | 2288-0771 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/5305 | - |
| dc.description.abstract | This study is focused on the root mean square and peak-to-valley based on the injection conditions of thef-theta lens, one of the main components of laser printers and laser scanning systems. The f-theta lens of anaspherical plastic lens requires ultra-preaction. Injection molding is typically used for the mass production ofaspherical plastic lenses. In the injection-molding method, the resin in the lens shape is filled with the resinafter melting the plastic pellets at a constant temperature and then cooled. It is necessary to maintain auniform injection molding system to produce high-quality lenses. These injection-molding systems areinfluenced by different factors, such as pressure, speed, temperature, mold, and cooling. It is possible toobtain a lens that exhibits the optical characteristics required to achieve harmony. We investigated the rootmean square and peak-to-valley caused by variations in temperature, a critical parameter in the melting andcooling of plastic resins generated inside and outside the injection mold. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국기계가공학회 | - |
| dc.title | Effect of Injection Temperature Condition on Root Mean Square and Peak-to-Valley of F-theta Lens | - |
| dc.title.alternative | Effect of Injection Temperature Condition on Root Mean Square and Peak-to-Valley of F-theta Lens | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.14775/ksmpe.2021.20.06.114 | - |
| dc.identifier.bibliographicCitation | 한국기계가공학회지, v.20, no.6, pp 114 - 120 | - |
| dc.citation.title | 한국기계가공학회지 | - |
| dc.citation.volume | 20 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 114 | - |
| dc.citation.endPage | 120 | - |
| dc.identifier.kciid | ART002725719 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Laser Scanning Unit | - |
| dc.subject.keywordAuthor | F-theta Lens | - |
| dc.subject.keywordAuthor | Injection | - |
| dc.subject.keywordAuthor | Root Mean Square | - |
| dc.subject.keywordAuthor | Peak to Valley | - |
| dc.subject.keywordAuthor | 레이저 스캐닝 유닛 | - |
| dc.subject.keywordAuthor | 에프세타 렌즈 | - |
| dc.subject.keywordAuthor | 사출성형 | - |
| dc.subject.keywordAuthor | 표면조도 | - |
| dc.subject.keywordAuthor | 표면형상 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.