Cited 0 time in
Wells-Riley 식을 활용한 초등학교 내 공기전파감염관리 항목의 적용 우선순위 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 정창헌 | - |
| dc.contributor.author | 황석호 | - |
| dc.date.accessioned | 2022-12-26T11:31:06Z | - |
| dc.date.available | 2022-12-26T11:31:06Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.issn | 1976-6483 | - |
| dc.identifier.issn | 2586-0666 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/5151 | - |
| dc.description.abstract | This study evaluated the impact of airborne infection prevention measures by Wells-Riley equation to provide basic information for infection control in elementary schools. At first, the Wells-Riley equation is modified to reflect prevention measures against airborne infection such as facial masks, ventilation and air purifiers. Afterward, 22 scenarios are established to evaluate the impact of airborne infection prevention measures. The results indicate infector screening by fever check is the most influential followed by hi-efficiency mask (KF94), ventilation, cotton-mask, air-purifier. Especially, when an infector is present, airborne infection risk can be reduced effectively only when both of wearing masks and ventilating are well done. Cotton-masks are useful but have limited effect, and air-purifiers can be used as auxiliary measures. | - |
| dc.format.extent | 10 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | Wells-Riley 식을 활용한 초등학교 내 공기전파감염관리 항목의 적용 우선순위 분석 | - |
| dc.title.alternative | Priority Analysis of Airborne Infection Prevention Measures Using Wells-Riley Equation | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.22696/jkiaebs.20210034 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.15, no.4, pp 395 - 404 | - |
| dc.citation.title | 한국건축친환경설비학회 논문집 | - |
| dc.citation.volume | 15 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 395 | - |
| dc.citation.endPage | 404 | - |
| dc.identifier.kciid | ART002746714 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Airborne infection | - |
| dc.subject.keywordAuthor | Wells-Riley equation | - |
| dc.subject.keywordAuthor | Priority analysis | - |
| dc.subject.keywordAuthor | Infection prevention | - |
| dc.subject.keywordAuthor | Elementary school | - |
| dc.subject.keywordAuthor | 공기전파감염 | - |
| dc.subject.keywordAuthor | 웰스-라일리 수식 | - |
| dc.subject.keywordAuthor | 우선순위분석 | - |
| dc.subject.keywordAuthor | 감염방지 | - |
| dc.subject.keywordAuthor | 초등학교 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.