Cited 0 time in
냉각탑의 어프로치 온도 감소를 위한 제어알고리즘 개발
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 하주완 | - |
| dc.contributor.author | 김유진 | - |
| dc.contributor.author | 김환용 | - |
| dc.contributor.author | 송영학 | - |
| dc.date.accessioned | 2022-12-26T11:16:36Z | - |
| dc.date.available | 2022-12-26T11:16:36Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.issn | 1976-6483 | - |
| dc.identifier.issn | 2586-0666 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/4932 | - |
| dc.description.abstract | The chiller efficiency is an important factor for improving the efficiency of the central chilled water system. A low-condenser water temperature is required for the low cooling tower leaving water temperature, which affects the chiller efficiency. Various studies have been conducted to produce low-condenser water temperature, but an additional review is needed on a method to lower the approach temperature. This study developed a control algorithm for cooling tower low-approach temperature. The approach temperature changes within the same load, ambient conditions according to the liquid-to-gas ratio (LGR), which is the operating condition of the cooling tower system. It found that the lower the LGR, the lower the approach temperature could be secured. As the approach temperature is lowered, it is expected that the efficiency of the chiller and cooling water pump will be improved. | - |
| dc.format.extent | 12 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | 냉각탑의 어프로치 온도 감소를 위한 제어알고리즘 개발 | - |
| dc.title.alternative | Development of Control Algorithm for Cooling Tower Low-Approach Temperature | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.22696/jkiaebs.20210037 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.15, no.5, pp 431 - 442 | - |
| dc.citation.title | 한국건축친환경설비학회 논문집 | - |
| dc.citation.volume | 15 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 431 | - |
| dc.citation.endPage | 442 | - |
| dc.identifier.kciid | ART002771523 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 냉각탑 제어 | - |
| dc.subject.keywordAuthor | 어프로치온도 | - |
| dc.subject.keywordAuthor | 저온 냉각수 | - |
| dc.subject.keywordAuthor | 냉각탑 출구온도 | - |
| dc.subject.keywordAuthor | 알고리즘 | - |
| dc.subject.keywordAuthor | Cooling tower control | - |
| dc.subject.keywordAuthor | Approach temperature | - |
| dc.subject.keywordAuthor | Low-condenser water temperature | - |
| dc.subject.keywordAuthor | Cooling tower leaving water temperature | - |
| dc.subject.keywordAuthor | Algorithm | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
