Cited 6 time in
Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Yon Kwon Ihn | - |
| dc.contributor.author | 김범수 | - |
| dc.contributor.author | 정해웅 | - |
| dc.contributor.author | 서상현 | - |
| dc.contributor.author | 원유동 | - |
| dc.contributor.author | 이영준 | - |
| dc.contributor.author | 김동준 | - |
| dc.contributor.author | 전평 | - |
| dc.contributor.author | 류창우 | - |
| dc.contributor.author | 서상일 | - |
| dc.contributor.author | 최대섭 | - |
| dc.contributor.author | 최시성 | - |
| dc.contributor.author | 김상흠 | - |
| dc.contributor.author | 변준수 | - |
| dc.contributor.author | 노지은 | - |
| dc.contributor.author | 송윤선 | - |
| dc.contributor.author | 정우상 | - |
| dc.contributor.author | 홍노아 | - |
| dc.contributor.author | 백상현 | - |
| dc.contributor.author | 박정진 | - |
| dc.contributor.author | 임수미 | - |
| dc.contributor.author | 김정재 | - |
| dc.contributor.author | 윤웅 | - |
| dc.date.accessioned | 2022-12-26T11:16:25Z | - |
| dc.date.available | 2022-12-26T11:16:25Z | - |
| dc.date.issued | 2021-11 | - |
| dc.identifier.issn | 2093-9043 | - |
| dc.identifier.issn | 2233-6273 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/4876 | - |
| dc.description.abstract | Purpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL). Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution. Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group. Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs. | - |
| dc.format.extent | 12 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한신경중재치료의학회 | - |
| dc.title | Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels | - |
| dc.title.alternative | Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5469/neuroint.2021.00437 | - |
| dc.identifier.scopusid | 2-s2.0-85166431834 | - |
| dc.identifier.wosid | 001003469700006 | - |
| dc.identifier.bibliographicCitation | Neurointervention, v.16, no.3, pp 240 - 251 | - |
| dc.citation.title | Neurointervention | - |
| dc.citation.volume | 16 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 240 | - |
| dc.citation.endPage | 251 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002773596 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kciCandi | - |
| dc.relation.journalResearchArea | Neurosciences & Neurology | - |
| dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
| dc.subject.keywordPlus | INTERVENTIONAL RADIOLOGY | - |
| dc.subject.keywordPlus | PATIENT | - |
| dc.subject.keywordPlus | FLUOROSCOPY | - |
| dc.subject.keywordPlus | EXPERIENCE | - |
| dc.subject.keywordPlus | EXPOSURE | - |
| dc.subject.keywordAuthor | Cerebral angiography | - |
| dc.subject.keywordAuthor | Diagnostic reference levels | - |
| dc.subject.keywordAuthor | Radiation monitoring | - |
| dc.subject.keywordAuthor | Intracranial aneurysm | - |
| dc.subject.keywordAuthor | Thrombectomy | - |
| dc.subject.keywordAuthor | Intracranial arteriovenous malformation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
