Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

전자식 비례 압력제어밸브 내 오일 오염 입자 제거 제어 알고리즘 검증

Full metadata record
DC Field Value Language
dc.contributor.author천수환-
dc.contributor.author박진감-
dc.contributor.author장경제-
dc.contributor.author심성보-
dc.contributor.author장민호-
dc.contributor.author이진웅-
dc.date.accessioned2022-12-26T11:01:12Z-
dc.date.available2022-12-26T11:01:12Z-
dc.date.issued2021-12-
dc.identifier.issn2671-7972-
dc.identifier.issn2671-7980-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/4638-
dc.description.abstractAn electro proportional pressure control valve is mainly used to control the clutch of an agricultural tractor’s automatic transmission. During transmission, the operating, hydraulic oil is mix with many kinds of contaminants. The contaminants can be trapped between the valve body and spool of the proportional pressure control valve leading to abnormal operating conditions and finally critical damage to the transmission hydraulic system. The present study aimed to verify the valve control algorithm as a basic study of developing control logic that removes contaminants between the spool and the body of the proportional pressure control valve. To develop the algorithm, MATLAB/SIMULINK was used. PWM method was used to control the applied solenoid coil current. The effectiveness of the algorithm was verified by comparing the actual pressure of the normal valve with the actual pressure of the abnormal valve. Based on the present study findings, when the algorithm was applied, the response of the valve pressure according to the current became stable and oil contaminated particles were removed. In the future study, the control algorithm will be optimized for the stability of the proportional pressure reducing valve, and it will be verified in consideration with the driving of the clutch.-
dc.format.extent8-
dc.language한국어-
dc.language.isoKOR-
dc.publisher사단법인 유공압건설기계학회-
dc.title전자식 비례 압력제어밸브 내 오일 오염 입자 제거 제어 알고리즘 검증-
dc.title.alternativeControl Algorithm for Removing Oil Contaminant Factor from Proportional Pressure Control Valve-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation드라이브·컨트롤, v.18, no.4, pp 1 - 8-
dc.citation.title드라이브·컨트롤-
dc.citation.volume18-
dc.citation.number4-
dc.citation.startPage1-
dc.citation.endPage8-
dc.identifier.kciidART002780740-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorProportional Pressure Control Valve-
dc.subject.keywordAuthorPulse Width Modulation-
dc.subject.keywordAuthorOil Contaminant Factor-
dc.subject.keywordAuthorCurrent Control-
dc.subject.keywordAuthor비례 압력제어밸브-
dc.subject.keywordAuthor펄스폭 변조-
dc.subject.keywordAuthor오일 오염 입자-
dc.subject.keywordAuthor전류제어-
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Kyung Je photo

Jang, Kyung Je
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE