A Study on the Analysis of Injection Molding of F-theta Lens
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박용우 | - |
dc.contributor.author | 문성민 | - |
dc.contributor.author | 류성기 | - |
dc.date.accessioned | 2022-12-26T11:01:00Z | - |
dc.date.available | 2022-12-26T11:01:00Z | - |
dc.date.issued | 2021 | - |
dc.identifier.issn | 1598-6721 | - |
dc.identifier.issn | 2288-0771 | - |
dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/4581 | - |
dc.description.abstract | In this study, we investigate the injection molding of f-theta lens, an important element of the laser scanning unit of laser printers and scanning systems. The f-theta lens is an aspherical plastic lens that must be molded with a precision of seconds. An injection molding method is often used for mass producing aspherical plastic lenses at a low cost. In the injection molding process, costs related to forming and injection are included. Therefore, in this study, to determine the shrinkage and deformation of injection molded f-theta lens, we predict the pressure and temperature distributions. Further, based on the analysis of the predictions, we maximize the design efficiency and verify the cost and development period reduction. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 한국기계가공학회 | - |
dc.title | A Study on the Analysis of Injection Molding of F-theta Lens | - |
dc.title.alternative | A Study on the Analysis of Injection Molding of F-theta Lens | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.14775/ksmpe.2021.20.01.001 | - |
dc.identifier.bibliographicCitation | 한국기계가공학회지, v.20, no.1, pp 1 - 6 | - |
dc.citation.title | 한국기계가공학회지 | - |
dc.citation.volume | 20 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 6 | - |
dc.identifier.kciid | ART002680384 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Laser Scanning Unit | - |
dc.subject.keywordAuthor | F-theta Lens | - |
dc.subject.keywordAuthor | Injection | - |
dc.subject.keywordAuthor | Resin | - |
dc.subject.keywordAuthor | Mold | - |
dc.subject.keywordAuthor | 레이저 스캐닝 유닛 | - |
dc.subject.keywordAuthor | 에프세타 렌즈 | - |
dc.subject.keywordAuthor | 사출성형 | - |
dc.subject.keywordAuthor | 수지 | - |
dc.subject.keywordAuthor | 금형 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0533
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.