Frost behavior in ambient air vaporizer
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이성우 | - |
| dc.contributor.author | 정수연 | - |
| dc.contributor.author | 최성웅 | - |
| dc.date.accessioned | 2022-12-26T11:00:55Z | - |
| dc.date.available | 2022-12-26T11:00:55Z | - |
| dc.date.issued | 2021-02 | - |
| dc.identifier.issn | 2234-7925 | - |
| dc.identifier.issn | 2765-4796 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/4547 | - |
| dc.description.abstract | A vaporizer is a device for vaporizing cryogenic liquids such as liquefied natural gas (LNG) using a high-temperature heat source. Among the various types of vaporizers, the ambient air vaporizer (AAV) uses air in the atmosphere as the heat exchange medium; therefore, it is regarded as an eco-friendly heat exchanger. However, owing to the fuzziness and frost formed on the surface of the AAV, the vaporization efficiency decreases. In this study, the frost generation and formation on AAVs were investigated. For evaluation of the AAV performance, the outlet temperature of the LNG and the thickness of the frost layer formed were observed for different numbers of fins and effects of different seasons. Finally, these were also measured considering different convective heat transfer coefficients to observe the effect of different convective conditions; in this case, the outlet temperature of the LNG was not influenced by different seasons. However, the frost thickness was found to be affected by different seasons. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국마린엔지니어링학회 | - |
| dc.title | Frost behavior in ambient air vaporizer | - |
| dc.title.alternative | Frost behavior in ambient air vaporizer | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5916/jamet.2021.45.1.17 | - |
| dc.identifier.bibliographicCitation | 한국마린엔지니어링학회지, v.45, no.1, pp 17 - 20 | - |
| dc.citation.title | 한국마린엔지니어링학회지 | - |
| dc.citation.volume | 45 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 17 | - |
| dc.citation.endPage | 20 | - |
| dc.identifier.kciid | ART002691767 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Frost | - |
| dc.subject.keywordAuthor | Ambient air vaporizer | - |
| dc.subject.keywordAuthor | LNG | - |
| dc.subject.keywordAuthor | Season | - |
| dc.subject.keywordAuthor | Humidity | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.