Cited 0 time in
폭발 하중에 대한 FRP 재킷 시스템이 보강된 철근콘크리트 기둥 해석 모델 개발
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 신지욱 | - |
| dc.date.accessioned | 2022-12-26T11:00:33Z | - |
| dc.date.available | 2022-12-26T11:00:33Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.issn | 1598-4095 | - |
| dc.identifier.issn | 2287-7401 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/4428 | - |
| dc.description.abstract | This paper aims to develop numerical models for seismically-deficient reinforced concrete columns retrofitted using a fiber-reinforced polymer jacketing system under blast loading scenarios. To accomplish the research goal, a coupling model reproducing blast loads was developed and implemented to the column model. The column model was validated with a past experimental study, and the blast responses were compared to the numerical responses produced by past researchers. The validated modeling method was implemented to the non-retrofitted and retrofitted column models to estimate the effectiveness of the retrofit system. Based on the numerical responses, the retrofit system can significantly reduce the peak dynamic responses under a given blast loading scenario. | - |
| dc.format.extent | 13 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국공간구조학회 | - |
| dc.title | 폭발 하중에 대한 FRP 재킷 시스템이 보강된 철근콘크리트 기둥 해석 모델 개발 | - |
| dc.title.alternative | Numerical Model of FRP Jacketed RC Column Under Blast Loading Scenario | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.9712/KASS.2021.21.2.81 | - |
| dc.identifier.bibliographicCitation | 한국공간구조학회지, v.21, no.2, pp 67 - 79 | - |
| dc.citation.title | 한국공간구조학회지 | - |
| dc.citation.volume | 21 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 67 | - |
| dc.citation.endPage | 79 | - |
| dc.identifier.kciid | ART002724825 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Blast load | - |
| dc.subject.keywordAuthor | Seismically-deficient reinforced concrete column | - |
| dc.subject.keywordAuthor | Fiber-reinforced polymer jacketing system | - |
| dc.subject.keywordAuthor | Effectiveness of retrofit system | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.