Percutaneous bridge plating of extra-articular distal fibular fracture for the of distal tibia III fracture*open access
- Authors
- Jung, Gu-Hee; Chung, HoeJeong; Baek, Seung-Hoon; Sohn, Hoon-Sang
- Issue Date
- Jan-2021
- Publisher
- Elsevier Taiwan
- Keywords
- Distal fibular fracture; Percutaneous bridge plating; Distal tibia open fracture; Simultaneous external fixation
- Citation
- Asian Journal of Surgery, v.44, no.1, pp 363 - 368
- Pages
- 6
- Indexed
- SCIE
SCOPUS
- Journal Title
- Asian Journal of Surgery
- Volume
- 44
- Number
- 1
- Start Page
- 363
- End Page
- 368
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/4297
- DOI
- 10.1016/j.asjsur.2020.09.016
- ISSN
- 1015-9584
0219-3108
- Abstract
- Purpose: The aim of this study is to conduct clinical and radiographic evaluations of the use of percutaneous bridge plating for distal fibular fractures combined with distal tibia type III open fractures. Methods: Thirty-four patients with acute distal third fibular shaft fractures (4F2A(c) and 4F2B(c) according to the AO/OTA classification) combined with distal tibia type III open fractures were enrolled. Concurrent fibular fractures were fixed with the percutaneous bridge plating simultaneously, while distal tibia open fractures were temporally stabilized with a spanning external fixator. Clinical and radiographic outcomes were evaluated using the Lower Extremity Functional Scale (LEFS), the proportional length difference of the fibula, the talocrural angle, the union rate of the fibula and tibia, the operation time, and complications at the final follow-up. Results: All fibular fractures healed with an average bone healing time of 20.7 6.3 weeks (range, 16-35). The mean proportional length difference was 0.492 0.732% compared with that in the uninjured fibula. The functional assessment result according to the LEFS was 74.0 +/- 3.70 points (range, 57-80). No cases of fibula fracture infection developed throughout the follow-up period in any of the patients. Iatrogenic postoperative superficial peroneal nerve injury was not found in any of the patients. Conclusion: With the perspective of minimizing soft tissue problems due to high-energy trauma, the application of percutaneous bridge plating for the treatment of distal fibular fractures can be an alternative to conventional treatment methods. (c) 2020 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medicine > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.