Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Restenosis of a drug eluting stent on the previous bioresorbable vascular scaffold successfully treated with a drug-coated balloon: A case report

Full metadata record
DC Field Value Language
dc.contributor.authorJang, Hyun Gyung-
dc.contributor.authorKim, Kyehwan-
dc.contributor.authorPark, Hyun Woong-
dc.contributor.authorKoh, Jin-Sin-
dc.contributor.authorJeong, Young-Hoon-
dc.contributor.authorPark, Jeong Rang-
dc.contributor.authorKang, Min Gyu-
dc.date.accessioned2022-12-26T10:45:56Z-
dc.date.available2022-12-26T10:45:56Z-
dc.date.issued2021-01-26-
dc.identifier.issn2307-8960-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/4214-
dc.description.abstractBACKGROUND The in-stent restenosis (ISR) rates are reportedly inconsistent despite the increased use of second-generation drug eluting stent (DES). Although bioresorbable vascular scaffold (BVS) have substantial advantages with respect to vascular restoration, the rate of scaffold thrombosis is higher with BVS than with DES. Optimal treatment strategies have not been established for DES-ISR to date. CASE SUMMARY We report on a case of a 60-year-old man patient with acute coronary syndrome. He had a history of ST-segment elevation myocardial infarction associated with very late scaffold thrombosis and treated with a DES. Coronary angiography revealed significant stenosis, suggesting DES-ISR on the previous BVS. Optical coherence tomography (OCT) identified a plaque rupture and a disrupted scaffold strut in the neointimal proliferation of DES. To treat the DES-ISR on the previous BVS, we opted for a drug-coated balloon (DCB) after a balloon angioplasty using a semi-compliant and non-compliant balloon. The patient did not experience adverse cardiovascular events on using a DCB following the use of intensive dual antiplatelet therapy and statin for 24 mo. CONCLUSION This case highlights the importance of OCT as an imaging modality for characterizing the mechanism of target lesion failure. The use of a DCB following the administration of optimal pharmacologic therapy may be an optimal strategy for the treatment and prevention of recurrent BVS thrombosis and DES-ISR.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherBAISHIDENG PUBLISHING GROUP INC-
dc.titleRestenosis of a drug eluting stent on the previous bioresorbable vascular scaffold successfully treated with a drug-coated balloon: A case report-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.12998/wjcc.v9.i3.758-
dc.identifier.scopusid2-s2.0-85100442522-
dc.identifier.wosid000613285000028-
dc.identifier.bibliographicCitationWORLD JOURNAL OF CLINICAL CASES, v.9, no.3, pp 758 - 763-
dc.citation.titleWORLD JOURNAL OF CLINICAL CASES-
dc.citation.volume9-
dc.citation.number3-
dc.citation.startPage758-
dc.citation.endPage763-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordAuthorBioresorbable vascular scaffold thrombosis-
dc.subject.keywordAuthorIn-stent restenosis-
dc.subject.keywordAuthorDrug-coated balloon-
dc.subject.keywordAuthorOptical coherence tomography-
dc.subject.keywordAuthorIntensive dual antiplatelet therapy-
dc.subject.keywordAuthorCase report-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE