Cited 12 time in
Corrosion Environment Monitoring of Local Structural Members of a Steel Truss Bridge under a Marine Environment
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ha, Min-Gyun | - |
| dc.contributor.author | Jeon, Seok Hyeon | - |
| dc.contributor.author | Jeong, Young-Soo | - |
| dc.contributor.author | Mha, Ho-Seong | - |
| dc.contributor.author | Ahn, Jin-Hee | - |
| dc.date.accessioned | 2022-12-26T10:45:36Z | - |
| dc.date.available | 2022-12-26T10:45:36Z | - |
| dc.date.issued | 2021-02 | - |
| dc.identifier.issn | 1598-2351 | - |
| dc.identifier.issn | 2093-6311 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/4121 | - |
| dc.description.abstract | Corrosion environment monitoring was conducted on the structural members of a steel bridge truss in a marine environment. The corrosion depth measured on exposed monitoring steel plates and the galvanic corrosion current measured by Atmospheric Corrosion Monitoring sensors attached to structural members were used to evaluate the local corrosion environment of each type of structural member in the steel bridge truss. From the evaluation results, the corrosion environment of the horizontal structural member was found to be worse than those of the other members, indicating that the horizontal members should be the primary target for monitoring and maintenance efforts. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN SOC STEEL CONSTRUCTION-KSSC | - |
| dc.title | Corrosion Environment Monitoring of Local Structural Members of a Steel Truss Bridge under a Marine Environment | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1007/s13296-020-00424-3 | - |
| dc.identifier.scopusid | 2-s2.0-85100172959 | - |
| dc.identifier.wosid | 000577942500001 | - |
| dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF STEEL STRUCTURES, v.21, no.1, pp 167 - 177 | - |
| dc.citation.title | INTERNATIONAL JOURNAL OF STEEL STRUCTURES | - |
| dc.citation.volume | 21 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 167 | - |
| dc.citation.endPage | 177 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002690546 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Construction & Building Technology | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
| dc.subject.keywordPlus | STRENGTH | - |
| dc.subject.keywordAuthor | Local corrosion environment | - |
| dc.subject.keywordAuthor | Monitoring | - |
| dc.subject.keywordAuthor | Steel bridge truss | - |
| dc.subject.keywordAuthor | Marine environment | - |
| dc.subject.keywordAuthor | Exposure test | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.