Detailed Information

Cited 5 time in webofscience Cited 6 time in scopus
Metadata Downloads

Repeatability of Spectral Domain Optical Coherence Tomography Measurements of Bruch's Membrane Opening-Minimum Rim Width in Epiretinal Membrane Patients with Peripapillary Involvement

Full metadata record
DC Field Value Language
dc.contributor.authorNam, Ki Yup-
dc.contributor.authorKim, Bum Jun-
dc.contributor.authorLee, Woo Hyuk-
dc.contributor.authorHan, Yong Seop-
dc.date.accessioned2022-12-26T10:16:06Z-
dc.date.available2022-12-26T10:16:06Z-
dc.date.issued2021-06-
dc.identifier.issn2077-0383-
dc.identifier.issn2077-0383-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/3634-
dc.description.abstractThe Bruch's membrane opening-minimum rim width (BMO-MRW) is a recently introduced parameter of the neuroretinal rim. We analyzed the repeatability of spectral-domain optical coherence tomography (SD-OCT) measurements of BMO-MRW in epiretinal membrane (ERM) patients with peripapillary involvement, since the surface around the optic disc is distorted in such patients. BMO-MRW and retinal nerve fiber layer (RNFL) thickness measurements were performed using SD-OCT in prospectively enrolled ERM patients and age-matched healthy control individuals. After two consecutive measurements with a 5 min interval, repeatability was analyzed using the intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CV). Fifty-two eyes of 52 ERM patients and 62 eyes of 62 healthy controls were included in the study. The ICCs of the mean BMO-MRW/RNFL thickness measurements were 0.999/0.985 in ERM eyes and 0.999/0.999 in normal eyes, respectively. The RC values of mean BMO-MRW/RNFL thickness measurements were 9.0/6.25 mu m in ERM eyes and 4.61/0.92 mu m in normal eyes, respectively. The CV values were 0.91% and 1.45% for BMO-MRW and RNFL thickness in ERM eyes, and 0.63% and 0.33% in normal eyes, respectively. In ERM eyes, the RC, CV of average BMO-MRW were 1.9 and 1.4 times greater than those of normal eyes, but 6.8 and 4.4 times greater for average RNFL thickness. BMO-MRW and RNFL thickness showed good repeatability in the diseased eyes with peripapillary involvement and healthy control eyes. Based on the ICC, RC, and CV values, the repeatability of BMO-MRW measurements in peripapillary membrane patients was better than that of RNFL thickness.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleRepeatability of Spectral Domain Optical Coherence Tomography Measurements of Bruch's Membrane Opening-Minimum Rim Width in Epiretinal Membrane Patients with Peripapillary Involvement-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/jcm10112240-
dc.identifier.scopusid2-s2.0-85114075575-
dc.identifier.wosid000660226400001-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL MEDICINE, v.10, no.11-
dc.citation.titleJOURNAL OF CLINICAL MEDICINE-
dc.citation.volume10-
dc.citation.number11-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusOPEN-ANGLE GLAUCOMA-
dc.subject.keywordPlusNERVE-FIBER LAYER-
dc.subject.keywordPlusPREVALENCE-
dc.subject.keywordPlusREPRODUCIBILITY-
dc.subject.keywordPlusASSOCIATIONS-
dc.subject.keywordAuthorBruch's membrane opening-minimum rim width-
dc.subject.keywordAuthorretinal nerve fiber layer-
dc.subject.keywordAuthorrepeatability-
dc.subject.keywordAuthorepiretinal membrane-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE