Detailed Information

Cited 4 time in webofscience Cited 4 time in scopus
Metadata Downloads

Repeatability of Spectral Domain Optical Coherence Tomography Measurements of Bruch's Membrane Opening-Minimum Rim Width in Epiretinal Membrane Patients with Peripapillary Involvementopen access

Authors
Nam, Ki YupKim, Bum JunLee, Woo HyukHan, Yong Seop
Issue Date
Jun-2021
Publisher
MDPI
Keywords
Bruch's membrane opening-minimum rim width; retinal nerve fiber layer; repeatability; epiretinal membrane
Citation
JOURNAL OF CLINICAL MEDICINE, v.10, no.11
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF CLINICAL MEDICINE
Volume
10
Number
11
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/3634
DOI
10.3390/jcm10112240
ISSN
2077-0383
2077-0383
Abstract
The Bruch's membrane opening-minimum rim width (BMO-MRW) is a recently introduced parameter of the neuroretinal rim. We analyzed the repeatability of spectral-domain optical coherence tomography (SD-OCT) measurements of BMO-MRW in epiretinal membrane (ERM) patients with peripapillary involvement, since the surface around the optic disc is distorted in such patients. BMO-MRW and retinal nerve fiber layer (RNFL) thickness measurements were performed using SD-OCT in prospectively enrolled ERM patients and age-matched healthy control individuals. After two consecutive measurements with a 5 min interval, repeatability was analyzed using the intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CV). Fifty-two eyes of 52 ERM patients and 62 eyes of 62 healthy controls were included in the study. The ICCs of the mean BMO-MRW/RNFL thickness measurements were 0.999/0.985 in ERM eyes and 0.999/0.999 in normal eyes, respectively. The RC values of mean BMO-MRW/RNFL thickness measurements were 9.0/6.25 mu m in ERM eyes and 4.61/0.92 mu m in normal eyes, respectively. The CV values were 0.91% and 1.45% for BMO-MRW and RNFL thickness in ERM eyes, and 0.63% and 0.33% in normal eyes, respectively. In ERM eyes, the RC, CV of average BMO-MRW were 1.9 and 1.4 times greater than those of normal eyes, but 6.8 and 4.4 times greater for average RNFL thickness. BMO-MRW and RNFL thickness showed good repeatability in the diseased eyes with peripapillary involvement and healthy control eyes. Based on the ICC, RC, and CV values, the repeatability of BMO-MRW measurements in peripapillary membrane patients was better than that of RNFL thickness.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE