Detailed Information

Cited 4 time in webofscience Cited 5 time in scopus
Metadata Downloads

Compressed sensing time-of-flight magnetic resonance angiography with high spatial resolution for evaluating intracranial aneurysms: comparison with digital subtraction angiography

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Donghyun-
dc.contributor.authorHeo, Young Jin-
dc.contributor.authorJeong, Hae Woong-
dc.contributor.authorBaek, Jin Wook-
dc.contributor.authorShin, Gi Won-
dc.contributor.authorJin, Sung-Chul-
dc.contributor.authorBaek, Hye Jin-
dc.contributor.authorRyu, Kyeong Hwa-
dc.contributor.authorKim, Kang Soo-
dc.contributor.authorKim, InSeong-
dc.date.accessioned2022-12-26T10:16:04Z-
dc.date.available2022-12-26T10:16:04Z-
dc.date.issued2021-06-
dc.identifier.issn1971-4009-
dc.identifier.issn2385-1996-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/3621-
dc.description.abstractBackground and purpose: Compressed sensing is used for accelerated acquisitions with incoherently under-sampled k-space data, and intracranial time-of-flight magnetic resonance angiography is suitable for compressed sensing. Compressed sensing time-of-flight is beneficial in decreasing acquisition time and increasing spatial resolution while maintaining acquisition time. In this retrospective study, we aimed to evaluate the image quality and diagnostic performance of compressed sensing time-of-flight with high spatial resolution and compare with parallel imaging time-of-flight using digital subtraction angiography as a reference. Material and methods: In total, 39 patients with 46 intracranial aneurysms underwent parallel imaging and compressed sensing time-of-flight in the same imaging session and digital subtraction angiography before or after magnetic resonance angiography. The overall image quality, artefacts and diagnostic confidence were assessed by two observers. The contrast ratio, maximal aneurysm diameters and diagnostic performance were evaluated. Results: Compressed sensing time-of-flight showed significantly better overall image quality, degree of artefacts and diagnostic confidence in both observers, with better inter-observer agreement. The contrast ratio was significantly higher for compressed sensing time-of-flight than for parallel imaging time-of-flight in both observers (source images, P < 0.001; maximum intensity projection images, P < 0.05 for both observers); however, the measured maximal diameters of aneurysms were not significantly different. Compressed sensing time-of-flight showed higher sensitivity, specificity, accuracy and positive and negative predictive values for detecting aneurysms than parallel imaging time-of-flight in both observers, with better inter-observer agreement. Compressed sensing time-of-flight was preferred over parallel imaging time-of-flight by both observers; however, parallel imaging time-of-flight was preferred in cases of giant and large aneurysms. Conclusions: Compressed sensing-time-of-flight provides better image quality and diagnostic performance than parallel imaging time-of-flight. However, neuroradiologists should be aware of under-sampling artefacts caused by compressed sensing.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherSAGE PUBLICATIONS INC-
dc.titleCompressed sensing time-of-flight magnetic resonance angiography with high spatial resolution for evaluating intracranial aneurysms: comparison with digital subtraction angiography-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1177/1971400920988099-
dc.identifier.scopusid2-s2.0-85100145397-
dc.identifier.wosid000626674300001-
dc.identifier.bibliographicCitationNEURORADIOLOGY JOURNAL, v.34, no.3, pp 213 - 221-
dc.citation.titleNEURORADIOLOGY JOURNAL-
dc.citation.volume34-
dc.citation.number3-
dc.citation.startPage213-
dc.citation.endPage221-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClassesci-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalWebOfScienceCategoryNeuroimaging-
dc.subject.keywordAuthorCompressed sensing-
dc.subject.keywordAuthortime-of-flight magnetic resonance angiography-
dc.subject.keywordAuthorcerebral aneurysm-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE