Cited 2 time in
Touchless Control of Picture Archiving and Communication System in Operating Room Environment: A Comparative Study of Input Methods
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Jung-Taek | - |
| dc.contributor.author | Cha, Yong-Han | - |
| dc.contributor.author | Yoo, Jun-Il | - |
| dc.contributor.author | Park, Chan-Ho | - |
| dc.date.accessioned | 2022-12-26T10:01:12Z | - |
| dc.date.available | 2022-12-26T10:01:12Z | - |
| dc.date.issued | 2021-09 | - |
| dc.identifier.issn | 2005-291x | - |
| dc.identifier.issn | 2005-4408 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/3338 | - |
| dc.description.abstract | Background: The advancement of computer information technology would maximize its potential in operating rooms with touchless input devices. A picture archiving and communication system (PACS) was compared with a touchless input device (LMC-GW), relaying to another person to control a mouse through verbal guidance, and directly controlling a mouse. Methods: Participants (n = 34; mean age, 29.6 years) were prospectively enrolled and given nine scenarios to compare the three methods. Each scenario consisted of eight tasks, which required 6 essential functions of PACS. Time elapsed and measurement values were recorded for objective evaluation, while subjective evaluation was conducted with a questionnaire. Results: In all 8 tasks, manipulation using the mouse took significantly less time than the other methods (all p < 0.05). Study selection, panning, zooming, scrolling, distance measuring, and leg length measurement took significantly less time when LMC-GW was used compared to relaying to another person (all p < 0.01), whereas there were no significant differences in time required for measuring the angles and windowing. Although the touchless input device provided higher accessibility and lower contamination risk, it was more difficult to handle than the other input methods (all p < 0.01). Conclusions: The touchless input device provided superior or equal performance to the method of verbal instruction in the environment of operating room. Surgeons agreed that the device would be helpful for manipulating PACS in operating rooms with less contamination risk and disturbance of workflow. The touchless input device can be an alternative option for direct manipulation of a mouse in operation rooms in the future. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN ORTHOPAEDIC ASSOC | - |
| dc.title | Touchless Control of Picture Archiving and Communication System in Operating Room Environment: A Comparative Study of Input Methods | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.4055/cios20004 | - |
| dc.identifier.scopusid | 2-s2.0-85114150314 | - |
| dc.identifier.wosid | 000687821900019 | - |
| dc.identifier.bibliographicCitation | CLINICS IN ORTHOPEDIC SURGERY, v.13, no.3, pp 436 - 446 | - |
| dc.citation.title | CLINICS IN ORTHOPEDIC SURGERY | - |
| dc.citation.volume | 13 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 436 | - |
| dc.citation.endPage | 446 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002789516 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | esci | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Orthopedics | - |
| dc.relation.journalWebOfScienceCategory | Orthopedics | - |
| dc.subject.keywordPlus | MOTION GESTURE CONTROL | - |
| dc.subject.keywordPlus | INTERVENTIONAL RADIOLOGY | - |
| dc.subject.keywordPlus | USER-INTERFACE | - |
| dc.subject.keywordPlus | NAVIGATION | - |
| dc.subject.keywordPlus | SOFTWARE | - |
| dc.subject.keywordPlus | SURGERY | - |
| dc.subject.keywordAuthor | Touchless | - |
| dc.subject.keywordAuthor | Mouse | - |
| dc.subject.keywordAuthor | Picture archiving and communication system | - |
| dc.subject.keywordAuthor | Operating room | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
