Detailed Information

Cited 7 time in webofscience Cited 8 time in scopus
Metadata Downloads

Ideal Nozzle Position During Pressurized Intraperitoneal Aerosol Chemotherapy in an Ex Vivo Model

Full metadata record
DC Field Value Language
dc.contributor.authorPiao, Jinlan-
dc.contributor.authorPark, Soo Jin-
dc.contributor.authorLee, Heesu-
dc.contributor.authorKim, Junsik-
dc.contributor.authorPark, Sunwoo-
dc.contributor.authorLee, Nara-
dc.contributor.authorKim, Se Ik-
dc.contributor.authorLee, Maria-
dc.contributor.authorSong, Gwonhwa-
dc.contributor.authorLee, Jung Chan-
dc.contributor.authorKim, Hee Seung-
dc.date.accessioned2022-12-26T09:46:19Z-
dc.date.available2022-12-26T09:46:19Z-
dc.date.issued2021-11-
dc.identifier.issn0250-7005-
dc.identifier.issn1791-7530-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/3089-
dc.description.abstractBackground/Aim: Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is known to show uneven distribution and penetration of agents based on the nozzle position. Thus, this study aimed to investigate the ideal nozzle position for maximizing drug delivery during PIPAC. Materials and Methods: We created 2 cm-, 4 cm-and 8 cm ex vivo models according to the distance from the bottom to the nozzle using 21x15x16 cm-sized sealable plastic boxes. After each set of eight normal peritoneal tissues from swine were placed at eight different points (A to H), we performed PIPAC, compared the methylene blue staining areas to investigate the distribution, and estimated the depth of concentrated diffusion (DCD) and the depth of maximal diffusion (DMD) of doxorubicin. Results: In terms of distribution, the 4 cm-and 8 cm-ex vivo models showed more stained faces than the 2 cm-ex vivo model. Regarding the penetration depth, the 4 cm-ex vivo model showed the highest DCD (mean; 244.1 mu m, C; 105.1 mu m, D; 80.9 mu m, E; 250.2 mu m, G; 250.2 mu m, H) and DMD (mean; 174.8 mu m, D; 162.7 mu m, E; 511.7 mu m, F; 522.2 mu m, G; 528.1 mu m, H) in the most points corresponding to 62.5%. Conclusion: The ideal nozzle position during PIPAC might be halfway between the nozzle inlet and the bottom in the ex vivo model.-
dc.format.extent10-
dc.language영어-
dc.language.isoENG-
dc.publisherInternational Institute of Anticancer Research-
dc.titleIdeal Nozzle Position During Pressurized Intraperitoneal Aerosol Chemotherapy in an Ex Vivo Model-
dc.typeArticle-
dc.publisher.location그리이스-
dc.identifier.doi10.21873/anticanres.15362-
dc.identifier.scopusid2-s2.0-85118799625-
dc.identifier.wosid000720241700017-
dc.identifier.bibliographicCitationAnticancer Research, v.41, no.11, pp 5489 - 5498-
dc.citation.titleAnticancer Research-
dc.citation.volume41-
dc.citation.number11-
dc.citation.startPage5489-
dc.citation.endPage5498-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOncology-
dc.relation.journalWebOfScienceCategoryOncology-
dc.subject.keywordPlusPERITONEAL CARCINOMATOSIS-
dc.subject.keywordPlusDISTRIBUTION PATTERN-
dc.subject.keywordPlusDOXORUBICIN-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusPIPAC-
dc.subject.keywordAuthorNozzle-
dc.subject.keywordAuthorpressurized intraperitoneal aerosol chemotherapy-
dc.subject.keywordAuthorex vivo model-
dc.subject.keywordAuthorperitoneal metastasis-
dc.subject.keywordAuthorintraperitoneal chemotherapy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
자연과학대학 > 항노화신소재과학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Sun Woo photo

Park, Sun Woo
자연과학대학 (항노화신소재과학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE