Detailed Information

Cited 3 time in webofscience Cited 2 time in scopus
Metadata Downloads

Percutaneous Thrombin Injection Based on Computational Fluid Dynamics of Femoral Artery Pseudoaneurysmsopen access

Authors
Kim, Hyoung-HoKim, Kyung-WukLee, ChangjeChoi, Young HoKim, Min UkBaba, Yasutaka
Issue Date
Nov-2021
Publisher
KOREAN RADIOLOGICAL SOC
Keywords
Femoral artery; False aneurysm; Thrombin; Injections
Citation
KOREAN JOURNAL OF RADIOLOGY, v.22, no.11, pp 1834 - 1840
Pages
7
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN JOURNAL OF RADIOLOGY
Volume
22
Number
11
Start Page
1834
End Page
1840
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/3082
DOI
10.3348/kjr.2020.1340
ISSN
1229-6929
2005-8330
Abstract
Objective: To analyze the computational fluid dynamics (CFD) of femoral artery pseudoaneurysm (FAP), identify a suitable location and timing for percutaneous thrombin injection (PTI) based on this analysis, and report our clinical experience with the procedure. Materials and Methods: CFD can be used to analyze the hemodynamics of the human body. An analysis using CFD recommended that the suitable location of the needle tip for PTI is at the center of the aneurysm sac and the optimal timing for starting PTI is during the early inflow phase of blood into the sac. Since 2011, seven patients (three male and four female; median age, 60 years [range, 43-75 years]) with FAP were treated with PTI based on the devised suitable location and time. Prior to the procedure, color Doppler ultrasonography was performed to determine the location and timing of the thrombin injection. Results: The technical success rate of the PTI was 100%. The amount of thrombin used for the procedure ranged from 200 IU to 1000 IU (median, 500 IU). None of the patients experienced any symptoms or signs of embolic complications during the procedure. Follow-up CT images did not reveal any embolism in the lower extremities and showed complete thrombosis of the pseudoaneurysm. Conclusion: Based on our study of CFD, PTI administered centrally in the FAP during early inflow, as seen on color Doppler, can be an effective technique.
Files in This Item
There are no files associated with this item.
Appears in
Collections
융합기술공과대학 > 기계소재융합공학부 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyoung Ho photo

Kim, Hyoung Ho
우주항공대학 (항공우주공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE