| dc.description.abstract | A number of schools were closed due to the implementation of the small-scale school consolidation policy. The problem of neglecting closed schools is being solved by changing its purpose to office spaces, libraries, short-term residential facilities, and dormitories. However, old closed schools consume a lot of building energy due to insufficient thermal performance of the building envelope. Therefore, this study proposed energy retrofit of closed schools to reduce carbon emissions in the building sector. First, the building energy performance of the target building was diagnosed, and then the effect of improving the building energy performance by applying the retrofit package technology was analyzed. Finally, a repurposing was proposed to revitalize unused closed schools, and when the use was changed to a dormitory and all retrofit technologies were applied, the building energy consumption was reduced by 83%. | - |
| dc.format.extent | 10 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국생활환경학회 | - |
| dc.title | 역사적 가치를 가진 폐교의 활용을 위한 리트로핏 제안 | - |
| dc.title.alternative | A Retrofit Proposal for the Utilization of a Closed School with Historical Value | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.21086/ksles.2022.12.29.6.634 | - |
| dc.identifier.bibliographicCitation | 한국생활환경학회지, v.29, no.6, pp 634 - 643 | - |
| dc.citation.title | 한국생활환경학회지 | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 634 | - |
| dc.citation.endPage | 643 | - |
| dc.identifier.kciid | ART002922997 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Closed school | - |
| dc.subject.keywordAuthor | Diagnosis | - |
| dc.subject.keywordAuthor | Retrofit | - |
| dc.subject.keywordAuthor | Building energy performance | - |
| dc.subject.keywordAuthor | DesignBuilder | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.