Cited 0 time in
Repeatability of Bruch's Membrane Opening-minimum Rim Width in Age-related Macular Degeneration and Diabetic Macular Edema
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Bum Jun | - |
| dc.contributor.author | Lee, Woo Hyuk | - |
| dc.contributor.author | Nam, Ki Yup | - |
| dc.contributor.author | Kim, Ji Hye | - |
| dc.contributor.author | Kang, Tae Seen | - |
| dc.contributor.author | Cho, Hyun Kyung | - |
| dc.contributor.author | Han, Yong Seop | - |
| dc.date.accessioned | 2022-12-26T09:46:10Z | - |
| dc.date.available | 2022-12-26T09:46:10Z | - |
| dc.date.issued | 2021-11 | - |
| dc.identifier.issn | 0378-6471 | - |
| dc.identifier.issn | 2092-9374 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/3050 | - |
| dc.description.abstract | Purpose: To evaluate the repeatability of retinal nerve fiber layer (RNFL) thickness and Bruch's membrane opening-minimum rim width (BMO-MRVV) measurements by spectral-domain optical coherence tomography (SD-OCT) in wet age-related macular degeneration (wAMD) and diabetic macular edema (DME). Methods: This was a prospective study. The RNFL thickness and BMO-MRW parameters for each sector and global average were measured twice by SD-OCT. Repeatability was evaluated using the intraclass correlation coefficient (ICC) and coefficient of variation (CV). If the optic disc membrane was confirmed, it was analyzed by dividing it into three groups based on severity. Results: A total of 99 eyes (48 with wAMD, 51 with DME) were included in the analysis. The ICCs of the global RNFL thickness and global BMO-MRW measurements were 0.996 and 0.997, respectively, in wAMD and 0.994 and 0.996, respectively, in DME eyes. The CV values of global RNFL thickness and BMO-MRW were 0.60% and 0.73%, respectively, in wAMD eyes and 1.10% and 1.21%, respectively, in DME eyes. The disc membrane on the optic nerve head significantly affected global BMO-MRW repeatability (B = 0.814, p < 0.001). Conclusions: Both RNFL thickness and BMO-MRW measurements showed good repeatability in eyes with wAMD and DME. The severity of the optic disc membrane significantly affected the repeatability of BMO-MRW measurements in eyes with wAMD and DME. Therefore, physicians should examine the BMO-MRW in eyes with severe optic disc membrane. | - |
| dc.format.extent | 12 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한안과학회 | - |
| dc.title | Repeatability of Bruch's Membrane Opening-minimum Rim Width in Age-related Macular Degeneration and Diabetic Macular Edema | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3341/jkos.2021.62.11.1490 | - |
| dc.identifier.scopusid | 2-s2.0-85120777508 | - |
| dc.identifier.wosid | 000728495400005 | - |
| dc.identifier.bibliographicCitation | 대한안과학회지, v.62, no.11, pp 1490 - 1501 | - |
| dc.citation.title | 대한안과학회지 | - |
| dc.citation.volume | 62 | - |
| dc.citation.number | 11 | - |
| dc.citation.startPage | 1490 | - |
| dc.citation.endPage | 1501 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002774416 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | esci | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Ophthalmology | - |
| dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
| dc.subject.keywordPlus | NERVE-FIBER LAYER | - |
| dc.subject.keywordPlus | OPEN-ANGLE GLAUCOMA | - |
| dc.subject.keywordPlus | SPECTRAL-DOMAIN | - |
| dc.subject.keywordPlus | THICKNESS MEASUREMENTS | - |
| dc.subject.keywordPlus | CATARACT-SURGERY | - |
| dc.subject.keywordPlus | COHERENCE | - |
| dc.subject.keywordPlus | PREVALENCE | - |
| dc.subject.keywordPlus | DISEASE | - |
| dc.subject.keywordAuthor | Bruch's membrane opening-minimum rim width | - |
| dc.subject.keywordAuthor | Repeatability | - |
| dc.subject.keywordAuthor | Retinal nerve fiber layer | - |
| dc.subject.keywordAuthor | Spectral-domain optical coherence tomography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
