Effects of Earmuffs and Eye Masks on Propofol Sedation during Spinal Anesthesia for Orthopedic Surgery: A Randomized Controlled Trial

Full metadata record
DC Field Value Language
dc.contributor.authorPark, J.-W.-
dc.contributor.authorBae, Sung Il-
dc.contributor.authorRyu, J.-
dc.contributor.authorChung, S.H.-
dc.contributor.authorDo, S.-H.-
dc.date.accessioned2023-03-24T08:53:11Z-
dc.date.available2023-03-24T08:53:11Z-
dc.date.issued2023-02-
dc.identifier.issn2077-0383-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/30339-
dc.description.abstractIntravenous sedative drugs are commonly administered during regional anesthesia. However, reducing the excessive use of sedatives while providing adequate sedation is important from the clinical perspective, since the use of sedatives can cause considerable complications. We hypothesized that the application of earmuffs and eye masks would help reduce the sedative dose required to maintain proper sedation by blocking external stimuli. Patients who underwent orthopedic surgery under spinal anesthesia were randomly allocated to the control (no intervention) or intervention group (wearing earmuffs and eye masks). Intravenous sedation was administered using target-controlled infusion of propofol. The target concentration was controlled to maintain a Modified Observer’s Assessment of Alertness and Sedation score of 3 or 4. The primary outcome was the intraoperative propofol requirement. We also investigated the incidence of apnea, and patient satisfaction. Propofol requirement was significantly lower in the intervention group than that in the control group (2.3 (2.0–2.7) vs. 3.1 (2.7–3.4) mg·kg−1·h−1; p < 0.001). Intraoperative apnea occurred less frequently (p = 0.038) and patient satisfaction was higher (p = 0.002) in the intervention group compared to the control group. This study demonstrated that the use of earmuffs and eye masks during sedation was associated with lower propofol requirement and improved sedation quality. © 2023 by the authors.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleEffects of Earmuffs and Eye Masks on Propofol Sedation during Spinal Anesthesia for Orthopedic Surgery: A Randomized Controlled Trial-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/jcm12030899-
dc.identifier.scopusid2-s2.0-85147801149-
dc.identifier.bibliographicCitationJournal of Clinical Medicine, v.12, no.3-
dc.citation.titleJournal of Clinical Medicine-
dc.citation.volume12-
dc.citation.number3-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorearmuffs-
dc.subject.keywordAuthoreye masks-
dc.subject.keywordAuthorpropofol-
dc.subject.keywordAuthorregional anesthesia-
dc.subject.keywordAuthorsedation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE