| dc.description.abstract | This study investigated the effect of the under-floor air distribution (UFAD) system compared to conventional mixed-mode ventilation system to prevent airborne pathogen spread in elementary school. To analysis airborne pathogen spread pattern, STAR-CCM+ is used. By applying the UFAD system airborne infection risk at region around the exhaust area of conventional ventilation system can be significantly reduced. However, increased infection risks around exhaust area of UFAD system still existed. Thus, it is recommended to install the exhaust vents (outlets) away from the breathing area. In addition, since both of conventional ventilation system and the UFAD systems have a high infection risk at the front of the classroom, novel method to reduce the infection risk from students to teachers should be considered. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | ELSEVIER | - |
| dc.title | Effect of under-floor air distribution system to prevent the spread of airborne pathogens in classrooms | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.csite.2021.101641 | - |
| dc.identifier.scopusid | 2-s2.0-85118672778 | - |
| dc.identifier.wosid | 000720793100060 | - |
| dc.identifier.bibliographicCitation | CASE STUDIES IN THERMAL ENGINEERING, v.28 | - |
| dc.citation.title | CASE STUDIES IN THERMAL ENGINEERING | - |
| dc.citation.volume | 28 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Thermodynamics | - |
| dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordAuthor | Under-floor air distribution | - |
| dc.subject.keywordAuthor | Airborne pathogen | - |
| dc.subject.keywordAuthor | Airborne infection | - |
| dc.subject.keywordAuthor | Ventilation | - |
| dc.subject.keywordAuthor | CFD simulation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.