Analysis of Air Supply Air Flow Rate Decrease by Accelerated Dust Load Experiments on Heat-Recovery Ventilator Air Filter

Full metadata record
DC Field Value Language
dc.contributor.author박병용-
dc.contributor.author정창헌-
dc.contributor.author신철웅-
dc.contributor.author류성용-
dc.date.accessioned2022-12-30T02:30:01Z-
dc.date.available2022-12-30T02:30:01Z-
dc.date.issued2022-12-
dc.identifier.issn2288-968X-
dc.identifier.issn2288-9698-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/29397-
dc.description.abstractPurpose: Recently, owing to the high concentration of fine dust, air filters have become essential in heat-recovery ventilators. In Korea, air filter performance is evaluated by the standard, “KS B 6141 Air Filter Units for Ventilation.” However, filter lifetime has not been examined. In this study, an accelerated test method for air filters was developed. In addition, the change in the supply air flow rate was analyzed under filter conditions. Method: The filter accelerated test conditions were identified, and the annual average concentration of fine dust in the atmosphere was determined. A vertical wind tunnel was built to evaluate the air filter lifetime. The ISO A2 dust was dosed to an air filter. In addition, the supply air flow rates were measured for the three products that the accelerated air filter used. Result: Under the lab test conditions, the supply air flow rate changed with the filter usage time and the air resistance. In the experiments, only ISO A2 dust was used. Subsequently, the effects of various particles were tested on the development of the acceleration test method for filters.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisher한국생태환경건축학회-
dc.titleAnalysis of Air Supply Air Flow Rate Decrease by Accelerated Dust Load Experiments on Heat-Recovery Ventilator Air Filter-
dc.title.alternativeAnalysis of Air Supply Air Flow Rate Decrease by Accelerated Dust Load Experiments on Heat-Recovery Ventilator Air Filter-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.12813/kieae.2022.22.6.015-
dc.identifier.bibliographicCitationKIEAE Journal, v.22, no.6, pp 15 - 20-
dc.citation.titleKIEAE Journal-
dc.citation.volume22-
dc.citation.number6-
dc.citation.startPage15-
dc.citation.endPage20-
dc.identifier.kciidART002908287-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorVentilation System-
dc.subject.keywordAuthorAir Filter-
dc.subject.keywordAuthorAccelerated Evaluation-
dc.subject.keywordAuthorSupply Air Flow Rate-
dc.subject.keywordAuthorTest-
dc.subject.keywordAuthor환기장치-
dc.subject.keywordAuthor에어필터-
dc.subject.keywordAuthor가속화 평가-
dc.subject.keywordAuthor급기풍량-
dc.subject.keywordAuthor시험-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cheong, Chang Heon photo

Cheong, Chang Heon
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE