Cited 0 time in
Analysis of Air Supply Air Flow Rate Decrease by Accelerated Dust Load Experiments on Heat-Recovery Ventilator Air Filter
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박병용 | - |
| dc.contributor.author | 정창헌 | - |
| dc.contributor.author | 신철웅 | - |
| dc.contributor.author | 류성용 | - |
| dc.date.accessioned | 2022-12-30T02:30:01Z | - |
| dc.date.available | 2022-12-30T02:30:01Z | - |
| dc.date.issued | 2022-12 | - |
| dc.identifier.issn | 2288-968X | - |
| dc.identifier.issn | 2288-9698 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/29397 | - |
| dc.description.abstract | Purpose: Recently, owing to the high concentration of fine dust, air filters have become essential in heat-recovery ventilators. In Korea, air filter performance is evaluated by the standard, “KS B 6141 Air Filter Units for Ventilation.” However, filter lifetime has not been examined. In this study, an accelerated test method for air filters was developed. In addition, the change in the supply air flow rate was analyzed under filter conditions. Method: The filter accelerated test conditions were identified, and the annual average concentration of fine dust in the atmosphere was determined. A vertical wind tunnel was built to evaluate the air filter lifetime. The ISO A2 dust was dosed to an air filter. In addition, the supply air flow rates were measured for the three products that the accelerated air filter used. Result: Under the lab test conditions, the supply air flow rate changed with the filter usage time and the air resistance. In the experiments, only ISO A2 dust was used. Subsequently, the effects of various particles were tested on the development of the acceleration test method for filters. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국생태환경건축학회 | - |
| dc.title | Analysis of Air Supply Air Flow Rate Decrease by Accelerated Dust Load Experiments on Heat-Recovery Ventilator Air Filter | - |
| dc.title.alternative | Analysis of Air Supply Air Flow Rate Decrease by Accelerated Dust Load Experiments on Heat-Recovery Ventilator Air Filter | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.12813/kieae.2022.22.6.015 | - |
| dc.identifier.bibliographicCitation | KIEAE Journal, v.22, no.6, pp 15 - 20 | - |
| dc.citation.title | KIEAE Journal | - |
| dc.citation.volume | 22 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 15 | - |
| dc.citation.endPage | 20 | - |
| dc.identifier.kciid | ART002908287 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Ventilation System | - |
| dc.subject.keywordAuthor | Air Filter | - |
| dc.subject.keywordAuthor | Accelerated Evaluation | - |
| dc.subject.keywordAuthor | Supply Air Flow Rate | - |
| dc.subject.keywordAuthor | Test | - |
| dc.subject.keywordAuthor | 환기장치 | - |
| dc.subject.keywordAuthor | 에어필터 | - |
| dc.subject.keywordAuthor | 가속화 평가 | - |
| dc.subject.keywordAuthor | 급기풍량 | - |
| dc.subject.keywordAuthor | 시험 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
