Cited 0 time in
버퍼의 넓이가 다른 스너버의 수치해석 비교
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이경환 | - |
| dc.contributor.author | 심규진 | - |
| dc.contributor.author | 이용훈 | - |
| dc.contributor.author | 정한식 | - |
| dc.contributor.author | 정효민 | - |
| dc.date.accessioned | 2022-12-27T07:08:47Z | - |
| dc.date.available | 2022-12-27T07:08:47Z | - |
| dc.date.issued | 2007 | - |
| dc.identifier.issn | 2713-8429 | - |
| dc.identifier.issn | 2713-8437 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/28651 | - |
| dc.description.abstract | Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with ping to causevibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and ping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materialy affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. The system usually comprises bottle volume, caled snubber. Snubber is one of the most important parts in hydrogen compressing system. It has installed reciprocating hydrogen compressor. One of these components is snubber which has function to reduce pulsation waveform and to remove the impurities in the hydrogen gas. A snubber has an inclined plate as a buffer, which is installed inside snubber. When the pressure los and the pulsation of pressure within a snubber is minimized, the snubber could get more aplicability. Therefore, a to find an optimum geometric size on a several snubbers which have different buffer width, has been conducted using a numerical analysis. | - |
| dc.format.extent | 6 | - |
| dc.publisher | 한국동력기계공학회 | - |
| dc.title | 버퍼의 넓이가 다른 스너버의 수치해석 비교 | - |
| dc.title.alternative | The CFD Analysis Comparison of Several Snubbers with different Buffer Width | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 동력시스템공학회지, v.11, no.4, pp 38 - 43 | - |
| dc.citation.title | 동력시스템공학회지 | - |
| dc.citation.volume | 11 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 38 | - |
| dc.citation.endPage | 43 | - |
| dc.identifier.kciid | ART001207381 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kciCandi | - |
| dc.subject.keywordAuthor | 수소가스 | - |
| dc.subject.keywordAuthor | 왕복동식 압축기 | - |
| dc.subject.keywordAuthor | 맥동압 | - |
| dc.subject.keywordAuthor | 변동 | - |
| dc.subject.keywordAuthor | 스너버 | - |
| dc.subject.keywordAuthor | 버퍼 | - |
| dc.subject.keywordAuthor | Hydrogen Gas | - |
| dc.subject.keywordAuthor | Reciprocating Compresor | - |
| dc.subject.keywordAuthor | Pulsation Pressure | - |
| dc.subject.keywordAuthor | Fluctuation | - |
| dc.subject.keywordAuthor | Snubber | - |
| dc.subject.keywordAuthor | Bufer | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.