Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[Ⅰ]

Full metadata record
DC Field Value Language
dc.contributor.author류재용-
dc.contributor.author서정민-
dc.contributor.author박정호-
dc.contributor.author전보경-
dc.contributor.author최금찬-
dc.contributor.author손영일-
dc.date.accessioned2022-12-27T07:06:02Z-
dc.date.available2022-12-27T07:06:02Z-
dc.date.issued2007-
dc.identifier.issn1225-4517-
dc.identifier.issn2287-3503-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/28540-
dc.description.abstractResearch results for the pressure drop variance depending on operation conditions such as change of inlet concentration, pulse interval, and face velocity, etc., in a pulse air jet-type bag filter show that while at 3kg/cm2 whose pulse pressure is low, it is good to make an pulse interval longer in order to form the first layer, it may not be applicable to industry because of a rapid increase in pressure. In addition, the change of inlet concentration contributes more to the increase of pressure drop than the pulse interval does. In order to reduce operation costs by minimizing filter drag of a filter bag at pulse pressure 5kg/cm2, the dust concentration should be minimized, and when the inlet dust loading is a lower concentration, the pulse interval in the operation should be less than 70 sec, but when inlet dust loading is a higher concentration, the pulse interval should be below 30 sec. In particular, in the case that inlet dust loading is a higher concentration, a high-pressure distribution is observed regardless of pulse pressure. This is because dust is accumulated continuously in the filter bag and makes it thicker as filtration time increases, and thus the pulse interval should be set to below 30 sec. If the equipment is operated at 1m/min of face velocity, while pressure drop is low, the bag filter becomes larger and thus, its economics are very low due to a large initial investment. Therefore, a face velocity of around 1.5 m/min is considered to be the optimal operation condition. At 1.5 m/min considered to be the most economical face velocity, if the pulse interval increases, since the amount of variation in filter drag is large, depending on the amount of inlet dust loading, the operation may be possible at a lower concentration when the pulse interval is 70 sec. However, for a higher concentration, either face velocity or pulse interval should be reduced.-
dc.format.extent10-
dc.publisher한국환경과학회-
dc.title충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[Ⅰ]-
dc.title.alternativeStudy on Filter Drag Due to the Change of Operation Conditions in a Pulse Air Jet-type Bag Filter[Ⅰ]-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation한국환경과학회지, v.16, no.4, pp 449 - 458-
dc.citation.title한국환경과학회지-
dc.citation.volume16-
dc.citation.number4-
dc.citation.startPage449-
dc.citation.endPage458-
dc.identifier.kciidART001199693-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorPressure drop-
dc.subject.keywordAuthorFace velocity-
dc.subject.keywordAuthorPulse interval-
dc.subject.keywordAuthorPulse pressure-
dc.subject.keywordAuthorPressure drop-
dc.subject.keywordAuthorFace velocity-
dc.subject.keywordAuthorPulse interval-
dc.subject.keywordAuthorPulse pressure-
Files in This Item
There are no files associated with this item.
Appears in
Collections
건설환경공과대학 > 환경공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jeong Ho photo

Park, Jeong Ho
건설환경공과대학 (환경공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE