Cited 116 time in
The simultaneous determination of coumarins in Angelica gigas root by high performance liquid chromatography-diode array detector coupled with electrospray ionization/mass spectrometry
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ahn, M.-J. | - |
| dc.contributor.author | Lee, M.K. | - |
| dc.contributor.author | Kim, Y.C. | - |
| dc.contributor.author | Sung, S.H. | - |
| dc.date.accessioned | 2022-12-27T06:47:17Z | - |
| dc.date.available | 2022-12-27T06:47:17Z | - |
| dc.date.issued | 2008 | - |
| dc.identifier.issn | 0731-7085 | - |
| dc.identifier.issn | 1873-264X | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/28115 | - |
| dc.description.abstract | An high performance liquid chromatography-diode array detector coupled with electrospray ionization/mass spectrometry (HPLC-DAD/MS) based method has been developed for the simultaneous determination of nine coumarin compounds, nodakenin (1), peucedanone (2), marmesin (3), decursinol (4), 7-hydroxy-6-(2R-hydroxy-3-methylbut-3-enyl)coumarin (5), demethylsuberosin (6), decursin (7), decursinol angelate (8) and isoimperatorin (9) in the Korean medicinal herb, Cham-Dang-Gui, the dried root of Angelica gigas (Umbelliferae). The methanol extracts were analyzed by HPLC using a reversed-phase C18 column (5 μm, 4.5 mm × 250 mm) using a gradient acetonitrile-water solvent system at a flow rate of 1.0 ml/min. The analysis of six coumarins (1, 3, 4 and 6-8) with DAD was done at 330 nm and showed excellent linearity (r2 = 0.998-0.999) in a range of 0.2-250 μg/ml for all the compounds. The average recoveries (n = 3) were between 96.5% and 110.8%. Identification of each peak was also discussed with the electrospray ionization multi-stage tandem mass spectroscopy (ESI-MSn). The amount of these coumarin compounds was evaluated in A. gigas samples. Meanwhile, three coumarins (2, 5 and 9) could not been quantified by DAD because these peaks were overlapped with others. Determination of these compounds could be successfully accomplished with the HPLC-ESI/MS in selected ion monitoring/selected reaction monitoring mode. ? 2007 Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.title | The simultaneous determination of coumarins in Angelica gigas root by high performance liquid chromatography-diode array detector coupled with electrospray ionization/mass spectrometry | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.jpba.2007.09.020 | - |
| dc.identifier.scopusid | 2-s2.0-37749050520 | - |
| dc.identifier.bibliographicCitation | Journal of Pharmaceutical and Biomedical Analysis, v.46, no.2, pp 258 - 266 | - |
| dc.citation.title | Journal of Pharmaceutical and Biomedical Analysis | - |
| dc.citation.volume | 46 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 258 | - |
| dc.citation.endPage | 266 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordAuthor | Angelica gigas | - |
| dc.subject.keywordAuthor | Coumarins | - |
| dc.subject.keywordAuthor | Electrospray ionization multi-stage tandem mass spectroscopy | - |
| dc.subject.keywordAuthor | High performance liquid chromatography-diode array detector coupled with electrospray ionization/mass spectrometry | - |
| dc.subject.keywordAuthor | Simultaneous determination | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
