Cited 0 time in
축류형 송풍기의 익단간극이 성능에 미치는 영향에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 조종현 | - |
| dc.contributor.author | 정양범 | - |
| dc.contributor.author | 김영철 | - |
| dc.contributor.author | 조수용 | - |
| dc.date.accessioned | 2022-12-27T06:22:51Z | - |
| dc.date.available | 2022-12-27T06:22:51Z | - |
| dc.date.issued | 2008 | - |
| dc.identifier.issn | 2287-9706 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/27744 | - |
| dc.description.abstract | Fan performances are obtained with various tip clearance gaps and stagger angles of the rotor. A tested fan is an axial-type fan of which the casing diameter is 806mm. Two different rotors are applied to this test. One is designed on the basis of the free vortex method along the radial direction and the other is designed using the forced vortex method. The operating conditions are varied to the ultimate off-design point as well as the deign point. Overall efficiency, total pressure and input power are compared with the tip clearance gaps and different stagger angle. The experimental results show that changing of the stagger angle has minor influence to the performance when the same rotor is applied. When the tip clearance gap is less than 5% of the rotor span, the overall efficiency, total pressure loss and input power reduction are varied linearly with the variation of the tip clearance gaps. On the design point, the overall efficiency is decreased to the rate of 2.8-2.9 to the increasing of the tip clearance, but the changing rate of the overall efficiency is alleviated when the fan operates at off-design points. In particular, this rate is more quickly declined on a fan with the rotor designed using the forced vortex method. The result of the total pressure shows that the pressure reduction rate is a 0.08-0.1 according to the tip clearance, and additionally the input power reduction rate is a 0.045-0.065 at design point. | - |
| dc.format.extent | 11 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국유체기계학회 | - |
| dc.title | 축류형 송풍기의 익단간극이 성능에 미치는 영향에 관한 연구 | - |
| dc.title.alternative | A Study of the Tip Clearance Effect to the Performance of an Axial-Type Fan | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국유체기계학회 논문집, v.11, no.6, pp 7 - 17 | - |
| dc.citation.title | 한국유체기계학회 논문집 | - |
| dc.citation.volume | 11 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 7 | - |
| dc.citation.endPage | 17 | - |
| dc.identifier.kciid | ART001292514 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Axial-Type Fan(축류형송풍기) | - |
| dc.subject.keywordAuthor | Tip Clearance(익단간극) | - |
| dc.subject.keywordAuthor | Fan Performance(송풍기성능) | - |
| dc.subject.keywordAuthor | Performance Prediction(성능예측) | - |
| dc.subject.keywordAuthor | Performance Test(성능시험) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.