Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

전자식 압력 통각계의 유용성

Full metadata record
DC Field Value Language
dc.contributor.author이중훈-
dc.contributor.author이재호-
dc.contributor.author신희석-
dc.contributor.author윤철호-
dc.contributor.author오민균-
dc.contributor.author권수현-
dc.date.accessioned2022-12-27T06:20:59Z-
dc.date.available2022-12-27T06:20:59Z-
dc.date.issued2008-
dc.identifier.issn2234-0645-
dc.identifier.issn2234-0653-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/27667-
dc.description.abstractObjective: To examine pressure pain threshold (PPT) on several skeletal muscles in upper extremity, trunk, and lower extremity by using electronic pressure algometer and to evaluate it's interrater reliability, reproducibility, difference between gender and dominance, correlation with body mass index, and comparison among each muscles.Method: Forty healthy adults (male 27, female 13) were examined by two raters and reexamined in the same order after a rest of 10 minute. PPT at the splenius capitis, upper trapezius, infraspinatus, lumbar paraspinal muscle, extensor carpi radialis, vastus medialis, and gluteus medius muscles of both side was measured by medical electronic algometer. Rate of force application was approximately 2 lb/sec. Body mass index (BMI) was estimated from the individual's body weight by the square of their height.Results: There were no statistical differences of PPTs at all muscles between two raters, between two test with time interval, and between dominant and nondominant side, respectively. PPT in man was higher than female at all muscles. There was significant correlation between BMI and PPT at lumbar paraspinal muscle, vastus medialis, and gluteus medius only in male. PPT was highest at lumbar paraspinal muscle and lowest at splenius capitis.Conclusion: Electronic pressure algometer is a reliable tool for evaluation of PPT which has high interrater reliability and high reproducibility and is not affected by dominance and location of muscles. Therefore, it is a useful clinical tool to compare PPT before and after treatment and to study the mechanism of musculoskeletal pain research program.-
dc.format.extent5-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한재활의학회-
dc.title전자식 압력 통각계의 유용성-
dc.title.alternativeUsefulness of Electronic Pressure Algometer in Evaluation of Pressure Pain Threshold in Normal Korean Adults-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitationAnnals of Rehabilitation Medicine, v.32, no.6, pp 698 - 702-
dc.citation.titleAnnals of Rehabilitation Medicine-
dc.citation.volume32-
dc.citation.number6-
dc.citation.startPage698-
dc.citation.endPage702-
dc.identifier.kciidART001303271-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorPressure pain threshold-
dc.subject.keywordAuthorPressure algometer-
dc.subject.keywordAuthorReliability-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Min Kyun photo

Oh, Min Kyun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE