Detailed Information

Cited 37 time in webofscience Cited 40 time in scopus
Metadata Downloads

Functional polyterthiophene-appended uranyl-salophen complex: Electropolymerization and ion-selective response for monohydrogen phosphate

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Junghwan-
dc.contributor.authorKang, Dong Min-
dc.contributor.authorShin, Sung Chul-
dc.contributor.authorChoi, Myong Yong-
dc.contributor.authorKim, Jineun-
dc.contributor.authorLee, Shim Sung-
dc.contributor.authorKim, Jae Sang-
dc.date.accessioned2022-12-27T06:10:05Z-
dc.date.available2022-12-27T06:10:05Z-
dc.date.issued2008-04-
dc.identifier.issn0003-2670-
dc.identifier.issn1873-4324-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/27429-
dc.description.abstractWe have synthesized a bis(terthiophene)-appended uranyl-salophen complex, comprising N,N'-bis[4-(5,2':5',2 ''-terthiophen-3'-yl)salicylidene]-1,2-ethanediamine-uranyl complexes (TUS), and used it as a monomer for the electrochemical polymerizations (poly-TUS) on glassy carbon surfaces to prepare functionalized conducting polymer (CP) films. The poly-TUS films prepared from propylene carbonate/0.1M tetrabutyl ammonium perchlorate (TBAP) on a glassy carbon electrode have both the functionality of ion-to-electron transducers (solid contact) and Lewis-acidic binding sites for a monohydrogen phosphate (MHP) ion-selective electrode (ISE). The CP/poly-TUS sensor showed a linear range between 1.0 x 10(-1) and 1.0 x 10(-4.5) M with a near-Nernstian behavior (-30.4 mV decade(-1)) at a pH of 8.2. The detection limit of the electrode was 10(-5.0) M and the response time was improved (<10 s) compared to that of conventional ISEs (<20 s). For comparison, a conventional ISE (with an internal aqueous solution) based on a TUS monomer/o-nitrophenyl octylether (o-NPOE)/polyvinyl chloride (PVC) liquid membrane with or without tridodecylmethylammonium chloride (TDMACl) as an additive was also constructed and its performance as an MHP-ISE were studied. The superior selectivity and sensitivity of the CP/poly-TUS sensor enabled the direct measurement of MHP in a wide variety of applications. (C) 2008 Elsevier B.V. All rights reserved.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleFunctional polyterthiophene-appended uranyl-salophen complex: Electropolymerization and ion-selective response for monohydrogen phosphate-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/j.aca.2008.03.008-
dc.identifier.scopusid2-s2.0-41749097619-
dc.identifier.wosid000255721800009-
dc.identifier.bibliographicCitationAnalytica Chimica Acta, v.614, no.1, pp 85 - 92-
dc.citation.titleAnalytica Chimica Acta-
dc.citation.volume614-
dc.citation.number1-
dc.citation.startPage85-
dc.citation.endPage92-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusCONDUCTING POLYMERS-
dc.subject.keywordPlusPOTENTIOMETRIC RESPONSE-
dc.subject.keywordPlusANION COMPLEXATION-
dc.subject.keywordPlusMEMBRANE-ELECTRODE-
dc.subject.keywordPlusNEUTRAL LIGANDS-
dc.subject.keywordPlusSENSORS-
dc.subject.keywordPlusCARRIER-
dc.subject.keywordPlusPOLYTHIOPHENE-
dc.subject.keywordPlusRECOGNITION-
dc.subject.keywordPlusPOLYPYRROLE-
dc.subject.keywordAuthorion-selective sensor-
dc.subject.keywordAuthorconducting polymer-
dc.subject.keywordAuthorpolyterthiophene derivatives-
dc.subject.keywordAuthormonohydrogen phosphate-
dc.subject.keywordAuthorion-selective electrode-
Files in This Item
There are no files associated with this item.
Appears in
Collections
자연과학대학 > 화학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher ,  photo

,
자연과학대학 (화학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE