Detailed Information

Cited 37 time in webofscience Cited 40 time in scopus
Metadata Downloads

Functional polyterthiophene-appended uranyl-salophen complex: Electropolymerization and ion-selective response for monohydrogen phosphate

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Junghwan-
dc.contributor.authorKang, Dong Min-
dc.contributor.authorShin, Sung Chul-
dc.contributor.authorChoi, Myong Yong-
dc.contributor.authorKim, Jineun-
dc.contributor.authorLee, Shim Sung-
dc.contributor.authorKim, Jae Sang-
dc.date.accessioned2022-12-27T06:10:05Z-
dc.date.available2022-12-27T06:10:05Z-
dc.date.issued2008-04-
dc.identifier.issn0003-2670-
dc.identifier.issn1873-4324-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/27429-
dc.description.abstractWe have synthesized a bis(terthiophene)-appended uranyl-salophen complex, comprising N,N'-bis[4-(5,2':5',2 ''-terthiophen-3'-yl)salicylidene]-1,2-ethanediamine-uranyl complexes (TUS), and used it as a monomer for the electrochemical polymerizations (poly-TUS) on glassy carbon surfaces to prepare functionalized conducting polymer (CP) films. The poly-TUS films prepared from propylene carbonate/0.1M tetrabutyl ammonium perchlorate (TBAP) on a glassy carbon electrode have both the functionality of ion-to-electron transducers (solid contact) and Lewis-acidic binding sites for a monohydrogen phosphate (MHP) ion-selective electrode (ISE). The CP/poly-TUS sensor showed a linear range between 1.0 x 10(-1) and 1.0 x 10(-4.5) M with a near-Nernstian behavior (-30.4 mV decade(-1)) at a pH of 8.2. The detection limit of the electrode was 10(-5.0) M and the response time was improved (<10 s) compared to that of conventional ISEs (<20 s). For comparison, a conventional ISE (with an internal aqueous solution) based on a TUS monomer/o-nitrophenyl octylether (o-NPOE)/polyvinyl chloride (PVC) liquid membrane with or without tridodecylmethylammonium chloride (TDMACl) as an additive was also constructed and its performance as an MHP-ISE were studied. The superior selectivity and sensitivity of the CP/poly-TUS sensor enabled the direct measurement of MHP in a wide variety of applications. (C) 2008 Elsevier B.V. All rights reserved.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleFunctional polyterthiophene-appended uranyl-salophen complex: Electropolymerization and ion-selective response for monohydrogen phosphate-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/j.aca.2008.03.008-
dc.identifier.scopusid2-s2.0-41749097619-
dc.identifier.wosid000255721800009-
dc.identifier.bibliographicCitationAnalytica Chimica Acta, v.614, no.1, pp 85 - 92-
dc.citation.titleAnalytica Chimica Acta-
dc.citation.volume614-
dc.citation.number1-
dc.citation.startPage85-
dc.citation.endPage92-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusCONDUCTING POLYMERS-
dc.subject.keywordPlusPOTENTIOMETRIC RESPONSE-
dc.subject.keywordPlusANION COMPLEXATION-
dc.subject.keywordPlusMEMBRANE-ELECTRODE-
dc.subject.keywordPlusNEUTRAL LIGANDS-
dc.subject.keywordPlusSENSORS-
dc.subject.keywordPlusCARRIER-
dc.subject.keywordPlusPOLYTHIOPHENE-
dc.subject.keywordPlusRECOGNITION-
dc.subject.keywordPlusPOLYPYRROLE-
dc.subject.keywordAuthorion-selective sensor-
dc.subject.keywordAuthorconducting polymer-
dc.subject.keywordAuthorpolyterthiophene derivatives-
dc.subject.keywordAuthormonohydrogen phosphate-
dc.subject.keywordAuthorion-selective electrode-
Files in This Item
There are no files associated with this item.
Appears in
Collections
자연과학대학 > 화학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Sung Chul photo

Shin, Sung Chul
자연과학대학 (화학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE