Cited 40 time in
Functional polyterthiophene-appended uranyl-salophen complex: Electropolymerization and ion-selective response for monohydrogen phosphate
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Junghwan | - |
| dc.contributor.author | Kang, Dong Min | - |
| dc.contributor.author | Shin, Sung Chul | - |
| dc.contributor.author | Choi, Myong Yong | - |
| dc.contributor.author | Kim, Jineun | - |
| dc.contributor.author | Lee, Shim Sung | - |
| dc.contributor.author | Kim, Jae Sang | - |
| dc.date.accessioned | 2022-12-27T06:10:05Z | - |
| dc.date.available | 2022-12-27T06:10:05Z | - |
| dc.date.issued | 2008-04 | - |
| dc.identifier.issn | 0003-2670 | - |
| dc.identifier.issn | 1873-4324 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/27429 | - |
| dc.description.abstract | We have synthesized a bis(terthiophene)-appended uranyl-salophen complex, comprising N,N'-bis[4-(5,2':5',2 ''-terthiophen-3'-yl)salicylidene]-1,2-ethanediamine-uranyl complexes (TUS), and used it as a monomer for the electrochemical polymerizations (poly-TUS) on glassy carbon surfaces to prepare functionalized conducting polymer (CP) films. The poly-TUS films prepared from propylene carbonate/0.1M tetrabutyl ammonium perchlorate (TBAP) on a glassy carbon electrode have both the functionality of ion-to-electron transducers (solid contact) and Lewis-acidic binding sites for a monohydrogen phosphate (MHP) ion-selective electrode (ISE). The CP/poly-TUS sensor showed a linear range between 1.0 x 10(-1) and 1.0 x 10(-4.5) M with a near-Nernstian behavior (-30.4 mV decade(-1)) at a pH of 8.2. The detection limit of the electrode was 10(-5.0) M and the response time was improved (<10 s) compared to that of conventional ISEs (<20 s). For comparison, a conventional ISE (with an internal aqueous solution) based on a TUS monomer/o-nitrophenyl octylether (o-NPOE)/polyvinyl chloride (PVC) liquid membrane with or without tridodecylmethylammonium chloride (TDMACl) as an additive was also constructed and its performance as an MHP-ISE were studied. The superior selectivity and sensitivity of the CP/poly-TUS sensor enabled the direct measurement of MHP in a wide variety of applications. (C) 2008 Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Functional polyterthiophene-appended uranyl-salophen complex: Electropolymerization and ion-selective response for monohydrogen phosphate | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.aca.2008.03.008 | - |
| dc.identifier.scopusid | 2-s2.0-41749097619 | - |
| dc.identifier.wosid | 000255721800009 | - |
| dc.identifier.bibliographicCitation | Analytica Chimica Acta, v.614, no.1, pp 85 - 92 | - |
| dc.citation.title | Analytica Chimica Acta | - |
| dc.citation.volume | 614 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 85 | - |
| dc.citation.endPage | 92 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordPlus | CONDUCTING POLYMERS | - |
| dc.subject.keywordPlus | POTENTIOMETRIC RESPONSE | - |
| dc.subject.keywordPlus | ANION COMPLEXATION | - |
| dc.subject.keywordPlus | MEMBRANE-ELECTRODE | - |
| dc.subject.keywordPlus | NEUTRAL LIGANDS | - |
| dc.subject.keywordPlus | SENSORS | - |
| dc.subject.keywordPlus | CARRIER | - |
| dc.subject.keywordPlus | POLYTHIOPHENE | - |
| dc.subject.keywordPlus | RECOGNITION | - |
| dc.subject.keywordPlus | POLYPYRROLE | - |
| dc.subject.keywordAuthor | ion-selective sensor | - |
| dc.subject.keywordAuthor | conducting polymer | - |
| dc.subject.keywordAuthor | polyterthiophene derivatives | - |
| dc.subject.keywordAuthor | monohydrogen phosphate | - |
| dc.subject.keywordAuthor | ion-selective electrode | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.