Detailed Information

Cited 22 time in webofscience Cited 30 time in scopus
Metadata Downloads

Experimental study on the characteristics of longitudinal fin air-heating vaporizers in different seasons

Authors
Jeong, Hyo MinChung, Han ShikDjajadiwinata, EldwinKim, Pil HwanLee, Yong Hun
Issue Date
May-2008
Publisher
KOREAN SOC MECHANICAL ENGINEERS
Keywords
LNG (liquefied natural gas); LN2 (liquid nitrogen); vaporizer; fin; super low temperature
Citation
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, v.22, no.5, pp 981 - 990
Pages
10
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY
Volume
22
Number
5
Start Page
981
End Page
990
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/27419
DOI
10.1007/s12206-007-1216-1
ISSN
1738-494X
1976-3824
Abstract
Air-heating vaporizers are usually used to regasify LNG at satellite areas because of the small demand for natural gas there. The common type of air heating vaporizer which exists in the market is the longitudinally finned type with 8 fins, 50mm fin length and 2mm fin thickness. To contribute in developing an efficient air-heating vaporizer, experiment on finned type air-heating vaporizer using 8 fins, 50mm fin length with 2mm fin thickness (8fin501e) -which exist in the market- and 4 fins, 75mm fin length with 2mm fin thickness (4fin75le), which is proposed, were conducted. Then, both types of vaporizers are compared. The experiments were conducted in one hour by varying the ambient condition and the length of the vaporizer. The ambient air was controlled so that it has the same condition (same temperature, humidity and air velocity) with air condition in every season available and the length was varied 4000mm, 6000mm and 8000mm for each type of vaporizer. Additional experiment with longer duration, i.e., 4 hours and in a single room condition was conducted to validate the previous result. In this experiment, the main aspects in analyzing the characteristics of the air heating vaporizer are the inlet-outlet enthalpy difference and the outlet temperature of the working fluid. LN2 is used to substitute LNG for safety reasons. The results show that the characteristics of the finned type 4fin75le vaporizer are comparable to the finned type 8fin50le vaporizer.