Cited 0 time in
소규모 음압터널환기방식 무창자돈사의 최적 환기 요건에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이승주 | - |
| dc.contributor.author | 장동일 | - |
| dc.contributor.author | Winson M. Gutierrez | - |
| dc.contributor.author | 박정식 | - |
| dc.contributor.author | 전상훈 | - |
| dc.contributor.author | 조형제 | - |
| dc.contributor.author | 오권영 | - |
| dc.contributor.author | 장홍희 | - |
| dc.date.accessioned | 2022-12-27T05:49:22Z | - |
| dc.date.available | 2022-12-27T05:49:22Z | - |
| dc.date.issued | 2009 | - |
| dc.identifier.issn | 1738-1266 | - |
| dc.identifier.issn | 2234-1862 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/26983 | - |
| dc.description.abstract | This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (5.2(W)×12.3(L)×2.3(H) m) with negative tunnel ventilating system using CFD (Computational Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 4 rooms (520(W)×300(L) cm), 3 fences (70(H) cm), 1 air inlet (350(W)×2(H) cm) and 1 exhaust fan (50(D) cm) and simulated using CFD code, FLUENT. The simulation results for the original weaning piglet house showed ununiform ventilation for each room. Therefore, to uniformly ventilate all rooms, the heights of the air inlet and first fence were modified to 3 cm and 100 cm, respectively. The simulation result for the modified weaning piglet house showed uniform ventilation for all rooms and the optimum air inlet velocity of 1.4 m/s. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국농업기계학회 | - |
| dc.title | 소규모 음압터널환기방식 무창자돈사의 최적 환기 요건에 관한 연구 | - |
| dc.title.alternative | Necessary Conditions for Optimal Ventilation of Small Windowless Piglet House with Negative Tunnel Ventilating System | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | Journal of Biosystems Engineering, v.34, no.1, pp 63 - 68 | - |
| dc.citation.title | Journal of Biosystems Engineering | - |
| dc.citation.volume | 34 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 63 | - |
| dc.citation.endPage | 68 | - |
| dc.identifier.kciid | ART001322983 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | weaning piglet house | - |
| dc.subject.keywordAuthor | tunnel ventilation | - |
| dc.subject.keywordAuthor | CFD simulation | - |
| dc.subject.keywordAuthor | air inlet | - |
| dc.subject.keywordAuthor | fence | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.