Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development and Evaluation of the Utility of a Respiratory Monitoring and Visual Feedback System for Radiotherapy Using Machine Vision Technology

Full metadata record
DC Field Value Language
dc.contributor.authorKim, C.H.-
dc.contributor.authorChoi, H.S.-
dc.contributor.authorKang, K.M.-
dc.contributor.authorJeong, B.K.-
dc.contributor.authorJeong, H.-
dc.contributor.authorHa, I.B.-
dc.contributor.authorSong, J.H.-
dc.date.accessioned2022-12-26T09:30:46Z-
dc.date.available2022-12-26T09:30:46Z-
dc.date.issued2022-03-
dc.identifier.issn2508-1888-
dc.identifier.issn2466-2461-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/2674-
dc.description.abstractBackground: We developed a machine vision technology program that tracks patients’ real-time breathing and automatically analyzes their breathing patterns. Materials and Methods: To evaluate its potential for clinical application, the image tracking performance and accuracy of the program were analyzed using a respiratory motion phantom. Changes in the stability and regularity of breathing were observed in healthy adult volunteers according to whether the breathing pattern mirrored the breathing guidance. Results and Discussion: Displacement within a few millimeters was observed in real-time with a clear resolution, and the image tracking ability was excellent. This result was consistent even in the sections where breathing patterns changed rapidly. In addition, the respiratory gating method that reflected the individual breathing patterns improved breathing stability and regularity in all volunteers. Conclusion: The findings of this study suggest that this technology can be used to set the appropriate window and the range of internal target volume by reflecting the patient’s breathing pattern during radiotherapy planning. However, further studies in clinical populations are required to validate this technology. Copyright ? 2022 The Korean Association for Radiation Protection-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherKorean Association for Radiation Protection-
dc.titleDevelopment and Evaluation of the Utility of a Respiratory Monitoring and Visual Feedback System for Radiotherapy Using Machine Vision Technology-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.14407/jrpr.2021.00024-
dc.identifier.scopusid2-s2.0-85129558451-
dc.identifier.wosid000899274600002-
dc.identifier.bibliographicCitationJournal of Radiation Protection and Research, v.47, no.1, pp 8 - 15-
dc.citation.titleJournal of Radiation Protection and Research-
dc.citation.volume47-
dc.citation.number1-
dc.citation.startPage8-
dc.citation.endPage15-
dc.type.docTypeArticle-
dc.identifier.kciidART002829229-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClassesci-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusGUIDED BREATH-HOLD-
dc.subject.keywordPlusREAL-TIME TUMOR-
dc.subject.keywordPlusRADIATION-THERAPY-
dc.subject.keywordPlusMOTION-
dc.subject.keywordPlusTRACKING-
dc.subject.keywordPlusREPRODUCIBILITY-
dc.subject.keywordAuthorMachine Vision-
dc.subject.keywordAuthorRadiotherapy-
dc.subject.keywordAuthorRespiration Guiding-
dc.subject.keywordAuthorRespiratory-Gated Radiation Therapy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Bae Kwon photo

Jeong, Bae Kwon
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE