Cited 0 time in
이동식 미분무수 노즐의 소화 특성에 대한 수치 시뮬레이션
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 배강열 | - |
| dc.contributor.author | 정희택 | - |
| dc.contributor.author | 김형범 | - |
| dc.contributor.author | 정인수 | - |
| dc.contributor.author | 김창 | - |
| dc.date.accessioned | 2022-12-27T05:34:30Z | - |
| dc.date.available | 2022-12-27T05:34:30Z | - |
| dc.date.issued | 2009 | - |
| dc.identifier.issn | 2713-8429 | - |
| dc.identifier.issn | 2713-8437 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/26687 | - |
| dc.description.abstract | In the present study, the numerical investigation has been carried out to see the effects of water mist sprays on the fire suppression mechanism. The special-purposed program named as FDS was used to simulate the interaction of fire plume and water mists. This program solves the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The computational domain was composed of a rectangular space dimensioned as L×W×H=4.0×4.0×2.5 m3 with a mist-injecting nozzle installed 1.0 m high from the fire pool. In this paper, two types of nozzles were chosen to compare the performance of the fire suppression. Numerical results showed that the nozzle, type A, with more orifices having smaller diameters had poorer performance than the other one, type B because the flow injected through side holes deteriorated the primary flow. The fire-extinguishing time of type A was 2.6 times bigger than that of type B. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국동력기계공학회 | - |
| dc.title | 이동식 미분무수 노즐의 소화 특성에 대한 수치 시뮬레이션 | - |
| dc.title.alternative | Thermal Numerical Simulation on Fire Suppression Characteristics through Mobile Mist Spray Nozzles | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 동력시스템공학회지, v.13, no.5, pp 25 - 33 | - |
| dc.citation.title | 동력시스템공학회지 | - |
| dc.citation.volume | 13 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 25 | - |
| dc.citation.endPage | 33 | - |
| dc.identifier.kciid | ART001389665 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 이동식 미분무수 노즐 | - |
| dc.subject.keywordAuthor | 화제억제 | - |
| dc.subject.keywordAuthor | 화재 시뮬레이터 | - |
| dc.subject.keywordAuthor | 소화시간 | - |
| dc.subject.keywordAuthor | Mobile Mist Spray Nozzle | - |
| dc.subject.keywordAuthor | Fire Suppression | - |
| dc.subject.keywordAuthor | FDS(Fire Dynamic Simulator) | - |
| dc.subject.keywordAuthor | Extinguishing Time | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.