Cited 0 time in
흡입관 주위에 형성된 공기차단막이 흡입성능에 미치는 영향
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 조종현 | - |
| dc.contributor.author | 김재실 | - |
| dc.contributor.author | 조수용 | - |
| dc.date.accessioned | 2022-12-27T05:34:19Z | - |
| dc.date.available | 2022-12-27T05:34:19Z | - |
| dc.date.issued | 2009 | - |
| dc.identifier.issn | 2287-9706 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/26680 | - |
| dc.description.abstract | A study is conducted to improve the suction performance on suction devices which are used to remove polluted air generated by welding or machining process in a spacious working place of industry. Air-curtain is applied around the inlet of suction duct to interrupt the inflow of fresh air from the downstream region where is located opposite to the polluted air source. Two different air-curtain devices, such as a 45o backward and a fully backward, are adopted. Suction region is experimentally investigated by measuring the suction velocities using a hot-wire anemometer. Contours of the suction velocity are compared with the computed results. The suction condition is selected to 110,000 Reynolds number which is widely used on typical suction devices, and a width of blowing passage for creating the air-curtain is chosen to 9.38% of the suction duct diameter. The experimental results show that the suction performance obtained with the 45o backward air-curtain was better than that obtained with the fully backward air-curtain. On the suction duct using the 45o backward air-curtain, the suction region estimated on basis of the 0.4m/sec is improved by 66% at the same input power. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국유체기계학회 | - |
| dc.title | 흡입관 주위에 형성된 공기차단막이 흡입성능에 미치는 영향 | - |
| dc.title.alternative | Effect of the Suction Performance by the Air-Curtain Blowing around a Suction Duct | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국유체기계학회 논문집, v.12, no.5, pp 25 - 32 | - |
| dc.citation.title | 한국유체기계학회 논문집 | - |
| dc.citation.volume | 12 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 25 | - |
| dc.citation.endPage | 32 | - |
| dc.identifier.kciid | ART001378949 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Suction Performance(흡입성능) | - |
| dc.subject.keywordAuthor | Air-Curtain(공기차단막) | - |
| dc.subject.keywordAuthor | Ventilation(환기) | - |
| dc.subject.keywordAuthor | Suction Region(흡입영역) Polluted Air(오염공기) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.