한우사 내 송풍팬의 최적 설치에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이승주 | - |
| dc.contributor.author | 장동일 | - |
| dc.contributor.author | 최윤혁 | - |
| dc.contributor.author | 양재웅 | - |
| dc.contributor.author | 민병주 | - |
| dc.contributor.author | Winson M. Gutierrez | - |
| dc.contributor.author | 장홍희 | - |
| dc.date.accessioned | 2022-12-27T04:35:05Z | - |
| dc.date.available | 2022-12-27T04:35:05Z | - |
| dc.date.issued | 2010 | - |
| dc.identifier.issn | 1738-1266 | - |
| dc.identifier.issn | 2234-1862 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/25536 | - |
| dc.description.abstract | The fans installed in standard Hanwoo loose barns (room size : 10 m (width) × 5 m (length)) are frequently used to reduce Hanwoo’s heat stress during hot weather and to dry the wet floor. However, the most effective method of installing fans has not been suggested yet. Therefore, this study was carried out to evaluate two methods of installing fans under the ceiling of Hanwoo loose barn by using CFD (Computational Fluid Dynamics) code, FLUENT and to recommend the optimum fan installing method. The fan installation options were fan tilting angles of 45° and 0° (horizontal). The fans of 1 m diameter were installed at 3m above floor. A velocity scale on 10 cm and 110 cm above floor and air flow pattern were used as the parameters to evaluate the fan installing methods. The fans tilted at 45° angle produced higher wind at 10 cm and 110cm above floor and more uniform air flow pattern, compared with the fans installed horizontally. Based on these results, fans tilted at 45° angle may help to reduce Hanwoo’s heat stress and will dry the floor better than fans installed horizontally. Therefore, it is suggested that the fans of 1 m diameter in a standard Hanwoo loose barn should be installed at a 45° tilt angle and 3 m above floor with spacing of 5 m at the center of a room column. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국농업기계학회 | - |
| dc.title | 한우사 내 송풍팬의 최적 설치에 관한 연구 | - |
| dc.title.alternative | Study on Optimum Installation of Fan in Standard Hanwoo Loose Barn | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | Journal of Biosystems Engineering, v.35, no.5, pp 350 - 356 | - |
| dc.citation.title | Journal of Biosystems Engineering | - |
| dc.citation.volume | 35 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 350 | - |
| dc.citation.endPage | 356 | - |
| dc.identifier.kciid | ART001491546 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Hanwoo | - |
| dc.subject.keywordAuthor | Fan | - |
| dc.subject.keywordAuthor | Heat stress | - |
| dc.subject.keywordAuthor | Floor drying | - |
| dc.subject.keywordAuthor | Litter | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.