Cited 0 time in
다중이용시설 및 학교 교사내 실내공기중 섬유상 입자의 농도 특성
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박정호 | - |
| dc.contributor.author | 서정민 | - |
| dc.date.accessioned | 2022-12-27T04:22:37Z | - |
| dc.date.available | 2022-12-27T04:22:37Z | - |
| dc.date.issued | 2010 | - |
| dc.identifier.issn | 1225-4517 | - |
| dc.identifier.issn | 2287-3503 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/25309 | - |
| dc.description.abstract | his study was investigated the characteristics of indoor air concentration of fiber particles in 30 public facilities and 245 schools by PCM (phase contrast microscopy). Also SEM/EDX (scanning electron microscope / energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber and to classify asbestos and non-asbestos of fiber particles. The airborne concentrations of fiber particles were 0.0009±0.0009 counts/mL in public facilities and 0.0012±0.0006 counts/mL in schools by PCM. All the samples were satisfied with the IAQ (indoor air quality) level of 0.01counts/mL. In classification of 4 type shapes, over 80% of the fiber particles were identified as single fiber type. And this study analysed airborne fiber particles in 4 sites for identifying asbestos of by SEM/EDX. The asbestos fibers in most samples could not be found. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국환경과학회 | - |
| dc.title | 다중이용시설 및 학교 교사내 실내공기중 섬유상 입자의 농도 특성 | - |
| dc.title.alternative | Characterizations of Airborne Fiber Particle Concentrations in Public Facilities and Schools | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국환경과학회지, v.19, no.4, pp 509 - 516 | - |
| dc.citation.title | 한국환경과학회지 | - |
| dc.citation.volume | 19 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 509 | - |
| dc.citation.endPage | 516 | - |
| dc.identifier.kciid | ART001443923 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Indoor air | - |
| dc.subject.keywordAuthor | Fiber particle | - |
| dc.subject.keywordAuthor | Asbestos | - |
| dc.subject.keywordAuthor | PCM | - |
| dc.subject.keywordAuthor | SEM/EDX | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
