Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측

Full metadata record
DC Field Value Language
dc.contributor.author박태규-
dc.contributor.author정희택-
dc.contributor.author박준영-
dc.contributor.author성병일-
dc.date.accessioned2022-12-27T03:33:12Z-
dc.date.available2022-12-27T03:33:12Z-
dc.date.issued2011-
dc.identifier.issn1598-6071-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/24266-
dc.description.abstractThe turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ±20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ±40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.-
dc.format.extent7-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국전산유체공학회-
dc.title고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측-
dc.title.alternativeNUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation한국전산유체공학회지, v.16, no.3, pp 75 - 81-
dc.citation.title한국전산유체공학회지-
dc.citation.volume16-
dc.citation.number3-
dc.citation.startPage75-
dc.citation.endPage81-
dc.identifier.kciidART001589006-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor공력성능(Aerodynamic Performance)-
dc.subject.keywordAuthor깃 배치각(Stagger Angle)-
dc.subject.keywordAuthor터보 블로어(Turbo Blower)-
dc.subject.keywordAuthor입구안내익(Inlet Guide Vane)-
dc.subject.keywordAuthor디퓨저(Diffuser)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > Department of Mechanical Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE