Cited 0 time in
진공관형 집열기 히트파이프 접촉방식에 따른 집열성능 비교
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 윤지훈 | - |
| dc.contributor.author | 정인국 | - |
| dc.contributor.author | 이중섭 | - |
| dc.contributor.author | 정경택 | - |
| dc.contributor.author | 서정세 | - |
| dc.date.accessioned | 2022-12-27T03:19:36Z | - |
| dc.date.available | 2022-12-27T03:19:36Z | - |
| dc.date.issued | 2011 | - |
| dc.identifier.issn | 1598-6721 | - |
| dc.identifier.issn | 2288-0771 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/24067 | - |
| dc.description.abstract | In this study, it was compared collecting performance according to contact types between heatpipe and manifold of vacuum tube type solar collector. Between two types, direct contact type is better in collecting performance. On the other hand, Indirect type have advantage in maintenance. In the result of numerical analysis, As the temperature of heatpipe and flow rate of working fluid increased, difference of outlet mean temperature of two types became large. Also, it could be confirmed, as contact resistance between heatpipe and copper tube in indirect type increased, the difference increased too. Useful data in selection and design in vacuum tube type solar collector were proposed by the results of numerical analysis. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계가공학회 | - |
| dc.title | 진공관형 집열기 히트파이프 접촉방식에 따른 집열성능 비교 | - |
| dc.title.alternative | Comparison of Collecting Performance according to Contact Types of Heatpipe in Vacuum Tube Type Solar Collector | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국기계가공학회지, v.10, no.6, pp 122 - 127 | - |
| dc.citation.title | 한국기계가공학회지 | - |
| dc.citation.volume | 10 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 122 | - |
| dc.citation.endPage | 127 | - |
| dc.identifier.kciid | ART001610143 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Solar wCollector(집열기) | - |
| dc.subject.keywordAuthor | Heatpipe(히트파이프) | - |
| dc.subject.keywordAuthor | Manifold(분기관) | - |
| dc.subject.keywordAuthor | Contact type(접촉방식) | - |
| dc.subject.keywordAuthor | Contact Resistance(접촉저항) | - |
| dc.subject.keywordAuthor | Solar wCollector(집열기) | - |
| dc.subject.keywordAuthor | Heatpipe(히트파이프) | - |
| dc.subject.keywordAuthor | Manifold(분기관) | - |
| dc.subject.keywordAuthor | Contact type(접촉방식) | - |
| dc.subject.keywordAuthor | Contact Resistance(접촉저항) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
